EP-1375: Volumetric-modulated-arc-therapy versus 3D-conformal-radiotherapy for sarcoma of extremities
نویسندگان
چکیده
منابع مشابه
Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison
Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...
متن کاملCardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer
PURPOSE To retrospectively evaluate the cardiac exposure in three cohorts of lung cancer patients treated with dynamic conformal arc therapy (DCAT), intensity-modulated radiotherapy (IMRT), or volumetric modulated arc therapy (VMAT) at our institution in the past seven years. METHODS AND MATERIALS A total of 140 lung cancer patients were included in this institutional review board approved st...
متن کاملIntensity modulated radiation therapy versus volumetric intensity modulated arc therapy
The advanced developments in external beam radiation therapy (EBRT) over the past few decades have improved dose conformity to the target while minimizing dose to the surrounding organs at risk (OAR). Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are two commonly used EBRT techniques to treat cancer. In sliding window (SW) or dynamic IMRT, each radiati...
متن کاملVolumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
BACKGROUND To compare the RapidArc plan for primary hepatocellular carcinoma (HCC) with 3-D conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans using dosimetric analysis. METHODS Nine patients with unresectable HCC were enrolled in this study. Dosimetric values for RapidArc, IMRT, and 3DCRT were calculated for total doses of 45~50.4 Gy using 1.8 Gy/day. The parame...
متن کاملDosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...