francesca innocenti high-dependency unit, department of clinical and experimental medicine, azienda ospedaliero-universitaria careggi, firenze, italy; high-dependency unit, department of clinical and experimental medicine, azienda ospedaliero-universitaria careggi, firenze, italy. tel: +39-0557947748, fax: +39-0557947038

chiara donnini high-dependency unit, department of clinical and experimental medicine, azienda ospedaliero-universitaria careggi, firenze, italy

stella squarciotta high-dependency unit, department of clinical and experimental medicine, azienda ospedaliero-universitaria careggi, firenze, italy

eleonora de villa high-dependency unit, department of clinical and experimental medicine, azienda ospedaliero-universitaria careggi, firenze, italy

چکیده

patients and methods in 382 subjects admitted in the emergency department (ed), we evaluated maximal (volmax) and minimal (volmin) la volumes and la emptying fraction (la-ef), from rt-3d images, with a semiautomated border detection program. a follow-up was performed in order to evaluate all-cause mortality and new hospital admission for cardiovascular events. objectives aims of this study were: 1) to evaluate feasibility of rt-3d echocardiography for la evaluation in an acute care setting and in a population including a majority of critically ills; 2) to evaluate correlation between two-dimensional (2d) and rt-3d echocardiographic la quantitative evaluation; 3) to assess clinical consistency and prognostic value of la measurements obtained from rt-3d images in subjects without cv diseases and in patients with af and chf, evaluated in the acute phase of the disease. results the correlation between measures obtained from 2d and 3d was good (la volmax: r = 0.896, p < 0.001; volmin: r = 0.906, p < 0,001; la ef: r = 0.749, p < 0.001). among 77 normal subjects, people aged ≥ 65 years demonstrated comparable la dimensions with younger subjects (la volmax: 25 ± 11 vs 20 ± 7 ml/m2, volmin: 11 ± 7 vs 8 ± 5 ml/m2). subjects with normal left ventricular ejection fraction showed la volmax significantly lower than patients with lv systolic dysfunction or congestive heart failure (23 ± 11 vs 29 ± 10 vs 33 ± 12 ml/m2, p < 0.05). patients in atrial fibrillation showed a significantly dilated la compared with subjects in sinus rhytm (24 ± 11 vs 37 ± 22 ml/m2, p < 0.05). la dimensions were significantly higher in non-survivors (la volmax: 33 ± 9 vs 25 ± 9 ml/m2), in patients with a new hospital admission for cardiovascular disease (la volmax: 34 ± 13 vs 23 ± 10 ml/m2) or with a new af episode (la volmax: 40 ± 12 vs 24 ± 11 ml/m2, all p < 0.005). conclusions rt-3d evaluation of la volumes and function is feasible in a non selected series of critically ills. la dilation was associated with a worse outcome in terms of morbidity and mortality. background limited data are available about feasibility and clinical value of left atrium (la) quantitative evaluation obtained from real time 3d (rt-3d) echocardiography in critically ills.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of left atrial volumes and ejection force by real-time three-dimensional echocardiography.

We read with great interest the article by Zhong et al1 entitled ‘Effects of age and gender on left atrial ejection force and volume from real-time three-dimensional echocardiography’. The authors determined the normal reference values for left atrial (LA) volumes and LA ejection force (LAEF) assessed by real-time three-dimensional echocardiography (RT3DE). The study was interesting, but we hav...

متن کامل

Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography.

We tested the feasibility of real-time three-dimensional (3D) echocardiographic (RT3DE) imaging to measure left heart volumes at different gravity during parabolic flight and studied the effects of lower body negative pressure (LBNP) as a countermeasure. Weightlessness-related changes in cardiac function have been previously studied during spaceflights using both 2D and 3D echocardiography. Sev...

متن کامل

Evaluation of left atrial volume and function using single-beat real-time three-dimensional echocardiography in atrial fibrillation patients

BACKGROUND This study was aimed to evaluate the feasibility and accuracy of real-time three-dimensional echocardiography (RT-3DE) measurement of left atrial (LA) volume and function in comparison with two-dimensional echocardiography (2DE) measurements in atrial fibrillation (AF) patients. METHODS A total of 50 pairs of AF patients and healthy controls were enrolled in this study. Indexed LA ...

متن کامل

Evaluation of left atrial volume and function using single beat real time 3-demensional echocardiography in atrial fibrillation patients

Title: Evaluation of left atrial volume and function using single-beat real-time three-dimensional echocardiography in atrial fibrillation patients Authors: Qian Zhang ([email protected]) Ju-fang Wang ([email protected]) Qing-qing Dong ([email protected]) Qing Yan ([email protected]) Xiang-hong Luo ([email protected]) Xue-ying Wu ([email protected]) Jian Liu ([email protected]) Ya-ping Sun (...

متن کامل

Evaluation of left atrial volume and function in systemic sclerosis patients using speckle tracking and real-time three-dimensional echocardiography

OBJECTIVE The aim of the present study was to evaluate left atrial (LA) volume and functions using real-time three-dimensional echocardiography (RT3DE) and speckle tracking in systemic sclerosis (SSc) patients. METHODS The study was designed as a cross-sectional observational study. We studied 41 consecutive SSc patients (38 females, mean age: 49.5±11.6 years) and 38 healthy controls (35 fema...

متن کامل

Electro-Anatomic (CARTO) Mapping for Measurement of Left Atrial Volume: Validation Against Real-Time 3D Echocardiography

Background: Left atrial size is a determinant of atrial fibrillation ablation efficacy and embolic risk. The recent advent of real-time full-volume 3DE allows now rapid measurement of chamber volume more accurately than with standard two-dimensional echocardiography as volume is reconstructed from endocardial contours of the entire chamber without making geometric assumptions. Electro-anatomic ...

متن کامل