diagnostic values of laser fluorescence device with other techniques in occlusal caries detection

نویسندگان

m. biria assistant professor, department of pediatric dentistry, school of dentistry, shahid beheshti univers

m. moshfeghi assistant professor, department of oral and maxillofacial radiology, school of dentistry, shahid beh

a. akbarzadeh baghban assistant professor, department of biostatistics, school of dentistry, shahid beheshti university of

a. chehresaz dentist, private practice

چکیده

objective: the aim of the present study was to compare the performance of laser fluorescence (lf) method with other conventional diagnostic techniques in detection of small occlusal caries in permanent teeth. materials and methods: prior to this in vitro diagnostic study, a pilot study assessed intra- examiner reliability and reproducibility. the occlusal surfaces of 90 extracted human premolars were examined with four diagnostic methods: probing, visual inspection, bitewing (bw) radiographs, and lf. the teeth were then sectioned for the purpose of histological examination. the data were analyzed using spss 15 software, and sensitivity, specificity and other diagnostic criteria of the techniques were calculated. results: the intra-examiner reproducibility for probing and also radiographic techniques was 100%. the corresponded figure for lf (88%) was more than visual inspection (82%). the highest level of validity of the examiner turned out to be in probing technique (76.9%). sensitivity of visual inspection, probing, and lf methods was 54.5% and that of bw radiography was 27.5%. specificity and efficiency of lf method were 84.8% and 81.1%, respectively. probing and visual inspection showed the highest specificity (97.5% and 94.9, respectively) and efficiency (92.2% and 90%, respectively) among the methods. conclusion: specificity and efficiency of lf method were lower compared to those of other methods. among all the investigated methods, the most efficient methods in the diagnosis of small occlusal caries in permanent teeth were probing and visual inspection, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New methodology to assess activity status of occlusal caries in primary teeth using laser fluorescence device.

An in vivo study was conducted to verify the ability of laser fluorescence (LF) to assess the activity status of occlusal caries in primary teeth, using different air-drying times. Occlusal sites (707) were examined using LF (DIAGNOdent) after air-drying for 3 s and 15 s, and the difference between readings (DIF15 s-3 s) was calculated. For concurrent validation of LF, visual criteria-Nyvad (NY...

متن کامل

Detection of Non-Cavitated Occlusal Caries with Impedance Spectroscopy and Laser Fluorescence: an In Vitro Study

OBJECTIVE To evaluate the performance of an impedance spectroscopy technology for detecting non-cavitated occlusal caries lesions in permanent teeth in vitro. The method was compared with a commonly used laser fluorescence device and validated against histology. MATERIAL AND METHODOLOGY A non-cavitated sample of 100 extracted posterior teeth was randomly selected and assessed for caries on en...

متن کامل

Clinical effectiveness of laser fluorescence, visual inspection and radiography in the detection of occlusal caries.

The aim of this in vivo study was to compare a laser fluorescence (LF) device with Ekstrand's visual scoring system and radiographic assessment for detection of occlusal caries. Thirty-eight adults aged 19-35 years participated in the study; a total of 57 third molars with macroscopically intact occlusal surfaces were selected. Two examiners assessed 110 sites by visual inspection (VI), bitewin...

متن کامل

Effect of the calibration method of a laser fluorescence device for detecting occlusal caries in primary molars.

PURPOSE The purpose of this study was to verify the influence of individual calibration on sound tooth surfaces and the number of readings on in vitro performance of a laser fluorescence (LF) device to detect occlusal caries in primary teeth. METHODS After standard calibration (on the porcelain reference object), 72 clinically suspect sites on occlusal surfaces of 54 exfoliated or extracted (...

متن کامل

Diagnostic comparison of three groups of examiners using visual and laser fluorescence methods to detect occlusal caries in vitro.

BACKGROUND To evaluate the accuracy of the DIAGNOdent laser device (DD) for detecting occlusal fissure caries when used by three groups of examiners. METHODS Three final-year dental students (S), three General Dental Practitioners (G), and three Academic Clinicians (A) individually examined the non-cavitated occlusal surfaces of 25 extracted permanent molars using visual inspection (VI) then ...

متن کامل

Performance of visual inspection, electrical conductance and laser fluorescence in detecting occlusal caries in vitro.

The aim of this study was to compare visual inspection (VI) and electrical conductance (EC) and laser fluorescence (LF) measurements in detecting occlusal caries. VI was based on fissure discoloration and performed with the naked eye. EC was measured with the ECM device (Lode Diagnostic, Groningen, The Netherlands), and LF was assessed with the DIAGNOdent apparatus (KaVo, Biberach, Germany). In...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۶، شماره ۲، صفحات ۱-۵

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023