noise pollution in intensive care units and emergency wards

نویسندگان

gholamreza khademi department of pediatrics, imam reza hospital, mashhad university of medical sciences, mashhad, iran

masoumeh roudi department of audiology, imam reza hospital, mashhad university of medical sciences, mashhad, iran

ahmad shah farhat department of pediatrics, imam reza hospital, mashhad university of medical sciences, mashhad, iran

masoud shahabian general physician, mashhad university of medical sciences, mashhad, iran

چکیده

introduction: the improvement of technology has increased noise levels in hospital wards to higher than international standard levels (35-45 db). higher noise levels than the maximum level result in patient’s instability and dissatisfaction. moreover, it will have serious negative effects on the staff’s health and the quality of their services. the purpose of this survey is to analyze the level of noise in intensive care units and emergency wards of the imam reza teaching hospital, mashhad. procedure: this research was carried out in november 2009 during morning shifts between 7:30 to 12:00. noise levels were measured 10 times at 30-minute intervals in the nursing stations of 10 wards of the emergency, the intensive care units, and the nephrology and kidney transplant departments of imam reza university hospital, mashhad. the noise level in the nursing stations was tested for both the maximum level (lmax) and the equalizing level (leq). the research was based on the comparison of equalizing levels (leq) because maximum levels were unstable. results: in our survey the average level (leq) in all wards was much higher than the standard level. the maximum level (lmax) in most wards was 85-86 db and just in one measurement in the internal icu reached 94 db. the average level of leq in all wards was 60.2 db. in emergency units, it was 62.2 db, but it was not time related. the highest average level (leq) was measured at 11:30 am and the peak was measured in the nephrology nursing station. conclusion:  the average levels of noise in intensive care units and also emergency wards were  more than the standard levels and as it is known these wards have vital roles in treatment procedures, so more attention is needed in this area.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise Pollution in Intensive Care Units and Emergency Wards

Introduction: The improvement of technology has increased noise levels in hospital Wards to higher than international standard levels (35-45 dB). Higher noise levels than the maximum level result in patient’s instability and dissatisfaction. Moreover, it will have serious negative effects on the staff’s health and the quality of their services. The purpose of this survey is to analyze the leve...

متن کامل

Noise Pollution in Intensive Care Units and Emergency Wards

INTRODUCTION The improvement of technology has increased noise levels in hospital Wards to higher than international standard levels (35-45 dB). Higher noise levels than the maximum level result in patient's instability and dissatisfaction. Moreover, it will have serious negative effects on the staff's health and the quality of their services. The purpose of this survey is to analyze the level ...

متن کامل

Effect of the Training of Nurses on the Reduction of Noise Pollution in Intensive Care Units

Background & Aims: Noise pollution is becoming a severe issue for the patients admitted in intensive care units (ICUs). For the reduction of noise pollution in hospitals, researchers recommend proper training and adherence to protocols. The present study aimed to assess the effect of the training of nurses on the reduction of noise pollution in ICUs. Materials & Methods: This clinical trial wa...

متن کامل

Noise pollution in intensive care units: a systematic review article

*Corresponding author: Bahareh Imani. Department of Pediatrics, NICU Dr.Sheikh Hospital, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran E-mail: [email protected] Tel: 051-37275580 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons. org/licenses/by/3.0), which permits unrestricted use, distrib...

متن کامل

Family and anxiety in intensive care units

Introduction: The hospitalization of one of family members, especially in the intensive care ‎unit, as a crisis can cause anxiety of his family and relatives.‎ Objective: The aim of this study was to determine personal effective factors on patient ‎family members’ anxiety in intensive care units. ‎ Material and Methods: In this cross – sectional, descriptive study...

متن کامل

Palliative Care in Neonatal Intensive Care Units: Challenges and Solutions

Palliative care is a series of actions aiming to offer support to parents and their infants in order to improve their quality of life. Despite optimal outcomes, the provision of palliative care for infants and achieving these outcomes may be hardly feasible. The present study aimed to investigate the barriers to palliative care and gain insight into the solutions. Accordingly, the obstacles wer...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of otorhinolaryngology

جلد ۲۳، شماره ۴، صفحات ۱۴۱-۱۴۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023