Statistical validation of a new helical tomotherapy patient transfer station

نویسندگان

  • Audrey H. Zhuang
  • An Liu
  • Timothy E. Schultheiss
  • Jeffrey Y.C. Wong
چکیده

The purpose of this work is to evaluate statistically the accuracy of a patient transfer station (PTS, TomoTherapy Inc., Madison, WI) that automatically converts one planning-station-generated treatment plan to another one with a different beam model. In our department we have installed 2 HI*ART tomotherapy systems, and patients often need to be transferred from one tomotherapy unit to the other. Thirty patients who underwent patient transfer between the two systems were evaluated. For each patient, dose differences between his/her original plan and PTS-transferred plan were evaluated by comparing doses at 10 randomly selected positions in his/her CT images. The Pearson indexes were calculated to analyze the relationship of the deviations to other parameters, which include absolute dose levels, sites (targets or normal tissues), dose accuracy of original plans and that of transferred plans. The dose accuracy of a treatment plan was determined by comparing delivered doses at the center of a 30 cm x 30 cm x 12 cm solid water phantom to planned doses at the same position. The calculated dose difference between original and transferred plans was, on average, 0.8% +/- 0.5%; the maximum deviation in absolute values was 1.9% in target volumes and 2.5% in normal organs. The errors generated during PTS-based transferring process were random and did not show correlation with other parameters. The PTS took less than 10 minutes to generate a backup plan that is much less than 2 hours that is approximately needed to create a duplicate plan manually. The results show that a PTS-transferred plan is an acceptable match to the original plan. With a physician's approval, a transferred plan is acceptable for treatment without the necessity of being revalidated in phantom. Thus far, all of our PTS plans have been approved by the treating physician without further optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prostate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field

Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...

متن کامل

Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy

BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

History of tomotherapy.

Tomotherapy is the delivery of intensity modulated radiation therapy using rotational delivery of a fan beam in the manner of a CT scanner. In helical tomotherapy the couch and gantry are in continuous motion akin to a helical CT scanner. Helical tomotherapy is inherently capable of acquiring CT images of the patient in treatment position and using this information for image guidance. This revi...

متن کامل

Recent citations

Tomotherapy is the delivery of intensity modulated radiation therapy using rotational delivery of a fan beam in the manner of a CT scanner. In helical tomotherapy the couch and gantry are in continuous motion akin to a helical CT scanner. Helical tomotherapy is inherently capable of acquiring CT images of the patient in treatment position and using this information for image guidance. This revi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009