The role of ultrasonography in examination of the stability of Tile-B2 pelvic fractures

نویسندگان

  • Bin-Fei Zhang
  • Hong Zhang
  • Peng-Fei Wang
  • Hu Wang
  • Jin-Lai Lei
  • Ya-Hui Fu
  • Yu-Xuan Cong
  • Hai Huang
  • Xiao-Ming Huo
  • Yan Zhuang
  • Kun Zhang
چکیده

BACKGROUND Determining whether a Tile-B2 pelvic fracture is stable is very challenging. We sought to identify the role of ultrasonography in determining the stability of Tile-B2 pelvic fractures. METHODS We collected the clinical data of patients with Tile-B2 pelvic fractures who presented at Xi'an Hong-Hui Hospital between June 1, 2016, and August 5, 2016. The treatment strategy of each patient was determined by a team of senior surgeons in the department. A single sinologist observed the movement of the fracture sites in patients during rest, under compression, and during separation to determine fracture stability. According to the pelvic fracture stability assessment, an appropriate treatment strategy was redetermined. Overall, 7 patients, including 5 women and 2 men, with Tile-B2 pelvic fractures were included in this case series. RESULTS During the initial examination, senior surgeons recommended that 2 patients should undergo internal fixation and 4 patients, conservative treatment; treatment was undecided for 1 patient. After ultrasonography examination, 4 patients underwent surgery via the Stoppa (n = 2) or ilioinguinal approach (n = 1) or cannulated screw fixation (n = 1). The rest of the patients (n = 3) received conventional treatment. Follow-up ranged from 6 to 10 months. Most of the patients showed excellent functions based on their last Majeed grading scores. There were no complications during the follow-up. Using ultrasonography examination, the preoperative treatment plan in 1 patient was changed, and the uncertain preoperative plan in 1 patient was identified. CONCLUSION Preoperative assessment of stability using ultrasonography may assist surgeons in making appropriate treatment choices for patients with Tile-B2 pelvic fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ultrasonography in Diagnosis of Nasal Fracture and Compared it with Plain Radiography in Dogs

Objective- One of the important causes of nasal fracture is a trauma that can be diagnosed in clinical examinations and diagnostic imaging but it should be noted that radiography may show false fractures in the nose. This study evaluates the value of ultrasonography in the diagnosis of nasal fractures and compared it with plain radiography. Design- Retrospective study. Animals- 12 d...

متن کامل

Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

OBJECTIVE This study aimed to compare the stability of Tile C pelvic fractures fixed with two iliosacral (IS) screws, tension band plate (TBP), and minimally invasive adjustable plate (MIAP). METHODS Six embalmed specimens of adult pelvis were used. The soft tissue was removed from the specimens, but spines from the fourth lumbar vertebra to the proximal one-third of both femurs were retained...

متن کامل

Comparative Evaluation of Ultrasound Against Conventional Radiography in Patients With Nasal Bone Fractures

Introduction: Nasal bone fractures are one of the most common problems in patients who are referred to otolaryngology centers. We aimed to evaluate physical examination, sonography and conventional lateral nasal bone radiography in patients with nasal bone trauma and its relation to intra-operative findings. Methods: This prospective study was performed on 200...

متن کامل

Biomechanical Comparison of Two Kinds of Internal Fixation in a Type C Zone II Pelvic Fracture Model

BACKGROUND Unstable pelvic fractures are complex and serious injuries. Selection of a fixation method for these fractures remains a challenging problem for orthopedic surgeons. This study aimed to compare the stability of Tile C pelvic fractures fixed with two iliosacral (IS) screws and minimally invasive adjustable plate (MIAP) combined with one IS screw. METHODS This study was a biomechanic...

متن کامل

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

 Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017