Kinetic sensitivity of a new lumbo-pelvic model to variation in segment parameter input.

نویسندگان

  • Helen Crewe
  • Amity Campbell
  • Bruce Elliott
  • Jacqueline Alderson
چکیده

This study aimed to assess variability in lumbo-pelvic forces and moments during a dynamic high-impact activity (cricket fast bowling) when calculated using different body segment parameters (BSPs). The first three BSPs were estimated using methods where the trunk was divided into segments according to nonspinal anatomical landmarks. The final approach defined segment boundaries according to vertebral level. Three-dimensional motion analysis data from nine male cricketers' bowling trials were processed using the four BSPs. A repeated-measures analysis of variance revealed no significant effect on peak lumbo-pelvic forces. However, the segmentation approach based on vertebral level resulted in significantly larger peak flexion and lateral flexion moments than the other BSP data sets. This has implications for comparisons between studies using different BSPs. Further, given that a method defined with reference to vertebral level more closely corresponds with relevant anatomical structures, this approach may more accurately reflect lumbar moments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Analysis of MPSIAC Model

MPSIAC is currently known as an appropriate method to measure sediment ofWatershed basins of the country while there has not been any sensitivity analysis so far forthis method. In this study, required data for MPSIAC model were gathered from six basins;Amame-Kamarkhani, Kand-Golandok, Tang Kenesht (from two different references), Nojian(from three different references), Pegahe sorkh katvand (f...

متن کامل

Modeling Discharge Coefficient of Side Weir on Converging Channel Using Extreme Learning Machine

In this study, the discharge coefficient of side weirs located on converging channels was simulated for the first time using a new method of Extreme Learning Machine (ELM). To examine the accuracy of the numerical model, the Monte Carlo simulations were used and the experimental values validation was conducted by the k-fold cross validation method. Then, the input parameters were detected for s...

متن کامل

How consistent are lordosis, range of movement and lumbo-pelvic rhythm in people with and without back pain?

BACKGROUND Comparing movements/postures in people with and without lower back pain (LBP) may assist identifying LBP-specific dysfunction and its relationship to pain or activity limitation. This study compared the consistency in lumbo-pelvic posture and movement (range and pattern) in people with and without chronic LBP (>12 week's duration). METHODS Wireless, wearable, inertial measurement u...

متن کامل

The Effect of Imagery and Corrective Exercises on Model of Activity of Selected Pelvic Muscles and the Lumbar Hyper Extension Syndrome

Introduction: Lumbar hyper extension syndrome is the second most common category of lumbar syndromes that reduces the height of the disc and narrows the intervertebral foramen in the lumbar vertebrae. The purpose of this study was the effect of exercises (imagery and corrective) on the degree of lumbar hyper extension and the activity of electromyography of the pelvic muscles. Methods: Twenty-...

متن کامل

The effects of bending speed on the lumbo-pelvic kinematics and movement pattern during forward bending in people with and without low back pain

BACKGROUND Impaired lumbo-pelvic movement in people with low back pain during bending task has been reported previously. However, the regional mobility and the pattern of the lumbo-pelvic movement were found to vary across studies. The inconsistency of the findings may partly be related to variations in the speed at which the task was executed. This study examined the effects of bending speeds ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 2013