Understanding the Discharge Activities in Transformer Oil under AC and DC Voltage Adopting UHF Technique

نویسندگان

  • R. Sarathi
  • G. Koperundevi
چکیده

Design of Converter transformer insulation is a major challenge. The insulation of these transformers is stressed by both AC and DC voltages. Particle contamination is one of the major problems in insulation structures, as they generate partial discharges leading it to major failure of insulation. Similarly corona discharges occur in transformer insulation. This partial discharge due to particle movement / corona formation in insulation structure under different voltage wave shapes, are different. In the present study, UHF technique is adopted to understand the discharge activity and could be realized that the characteristics of UHF signal generated under low and high fields are different. In the case of corona generated signal, the frequency content of the UHF sensor output lies in the range 0.3-1.2 GHz and is not much varied except for its increase in magnitude of discharge with the increase in applied voltage. It is realized that the current signal injected due to partial discharges/corona is about 4ns duration measured for first one half cycle. Wavelet technique is adopted in the present study. It allows one to identify the frequency content present in the signal at different instant of time. The STD-MRA analysis helps one to identify the frequency band in which the energy content of the UHF signal is maximum. Keywords—Contamination, Insulation, Partial Discharges, Transformer oil, UHF sensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber

Based on the physical phenomena of optical effects produced by the partial discharge (PD) and on the characteristics of fluorescent fiber sensing of weak fluorescent signals, a PD measurement system using a fluorescent fiber sensor was designed. The main parameters of the sensing system were calculated, an experimental testing platform for PD simulation in the lab was established, and PD signal...

متن کامل

Design and Simulation of a New DC Power Supply Based on Dual Bridge Matrix Converter

A conventional high power DC power supply systems consist of a three-phase diode rectifier followed by a high frequency converter to supply loads at regulated DC voltage. These rectifiers draw significant harmonic currents from the utility, resulting in poor input power factor. In this paper, a DC power supply based on dual-bridge matrix converter (DBMC) with reduced number of switches is p...

متن کامل

Partial Discharge of Needle-Plane Defect in Oil-Paper Insulation under AC and DC Combined Voltages: Developing Processes and Characteristics

Partial discharge (PD) behaviors of oil-paper insulation is distinctive in AC and DC combined electric fields in converter transformers from PD behaviors in pure AC or DC electric fields. The present study focuses on the PD developing processes and characteristics of oil-paper insulation systems with needle-plane defects under different AC/DC proportions. The degradation of oil-paper insulation...

متن کامل

Detection of Partial Discharges in Power Transformers using UHF PD Measurements and Acoustic Measurements

For examination and diagnostics of the insulation quality of high voltage devices the measurement of partial discharge (PD) is accomplished. The conventional PD measurement according to IEC60270 is in some situations not sensitive enough because of the high interference level in field. The development of an unconventional measuring method using electromagnetic probes is presented. These probes ...

متن کامل

A Novel Dynamic Voltage Regulator with a Multi-level AC/AC Converter

This article proposed a novel topology of dynamic voltage regulator using transformer and PWM multi-level AC/AC converter. In this paper for finding the best value of duty ratio for switches to minimize the THD, the GA algorithm has been used and THD output voltage is assumed to be fitness function. The proposed voltage regulator employs multi-level AC/AC converter to generate compensation volt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012