Evaluation of passive particle agglutination test for antibody to human immunodeficiency virus.

نویسندگان

  • T Yoshida
  • T Matsui
  • S Kobayashi
  • N Yamamoto
چکیده

A gelatin particle agglutination assay was compared with indirect immunofluorescence by using 663 serum samples from acquired immunodeficiency syndrome and acquired immunodeficiency syndrome-related complex patients and asymptomatic male homosexuals in the United States and from hemophiliacs and healthy adult controls in Japan. The results showed that all 104 samples which were positive by indirect immunofluorescence were also positive by particle agglutination, while 5 additional samples were positive by particle agglutination only. The coincidence rate for antibody-positive and antibody-negative specimens was 99% (658 of 663) between particle agglutination and immunofluorescence. Four of the five samples which were positive by particle agglutination only were found by radioimmunoprecipitation to contain anti-env gene products of human immunodeficiency virus. Antibody titers of samples giving a positive reaction by particular agglutination varied from low (titer, 256) to remarkably high (256 X 10(5)). All specimens having particle agglutination titers of more than 10(5) were positive by immunofluorescence. A high correlation (r = 0.66) was observed between the titers of antibodies determined by particle agglutination and those determined by immunofluorescence. After fractionation of a serum sample from an individual at high risk by using high-performance liquid chromatography, it was shown that immunoglobulin M as well as immunoglobulin G human immunodeficiency virus antibody was detected by particle agglutination. Additional serum samples with a potential risk of giving false-positive results, such as heat-treated specimens, specimens containing antibodies to HLA, specimens containing auto-antibodies, and serum samples from individuals with a history of multiple blood transfusions, were shown to be clearly negative by particle agglutination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of particle agglutination test for antibody to human immunodeficiency virus.

A comparative evaluation of a new serological test for human immunodeficiency virus (HIV) was carried out. The test used the agglutination of gelatin particles coated with HIV antigen. It was found to be more sensitive than current enzyme linked immunosorbent assays (ELISAs) and more specific than the western blot test. Because of its simplicity, it promises to be of value, especially in develo...

متن کامل

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

Preparation and evaluation of latex agglutination technique for diagnosis and seroepidemiological studies of visceral leishmaniasis

in this study which has been carried out from 1996 until 1997 soluble latex agglutination antigen was prepared from L, donovani,sudan(s-1) by culturing in special media,harvesting,and later solubilizing by freezing and thawing.the antigen were futher prepared by high speed centrifugation.after measurement of the protein (lowry method) concentration of the antigen was set at 2.2 mg/ml,the antige...

متن کامل

Tetanus and Diphtheria Seroprevalence in Patients Infected With Human Immunodeficiency Virus

Background and Objectives: HIV infected patients are at risk for vaccine-preventable infections such as tetanus and diphtheria (Td). In these patients, these antibodies tend to decline faster. Due to the limited data, this study assessed the seroprevalence of tetanus and diphtheria antibodies in HIV infected patients in Tehran, Iran. Materials and Methods: This case-control study was carried o...

متن کامل

Antibody Detection to Feline Immunodeficiency virus (FIV) in stray cats in Ahvaz, southwestern Iran

The present study was performed to determine the prevalence of FIV in stray cat's population of Ahvaz different area. Serum samples were collected from 90 cats from 2005 to 2007. The studied cats were divided into two age groups (3 years) and based on clinical signs (such as lymphadenopathy, periodontal diseases, gingivitis, abscess and cashecsi) into two groups also. The results were analyzed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 1987