Improving Image Quality of Bronchial Arteries with Virtual Monochromatic Spectral CT Images

نویسندگان

  • Guangming Ma
  • Taiping He
  • Yong Yu
  • Haifeng Duan
  • Chuangbo Yang
چکیده

OBJECTIVE To evaluate the clinical value of using monochromatic images in spectral CT pulmonary angiography to improve image quality of bronchial arteries. METHODS We retrospectively analyzed the chest CT images of 38 patients who underwent contrast-enhanced spectral CT. These images included a set of 140kVp polychromatic images and the default 70keV monochromatic images. Using the standard Gemstone Spectral Imaging (GSI) viewer on an advanced workstation (AW4.6,GE Healthcare), an optimal energy level (in keV) for obtaining the best contrast-to-noise ratio (CNR) for the artery could be automatically obtained. The signal-to-noise ratio (SNR), CNR and objective image quality score (1-5) for these 3 image sets (140kVp, 70keV and optimal energy level) were obtained and, statistically compared. The image quality score consistency between the two observers was also evaluated using Kappa test. RESULTS The optimal energy levels for obtaining the best CNR were 62.58±2.74keV.SNR and CNR from the 140kVp polychromatic, 70keV and optimal keV monochromatic images were (16.44±5.85, 13.24±5.52), (20.79±7.45, 16.69±6.27) and (24.9±9.91, 20.53±8.46), respectively. The corresponding subjective image quality scores were 1.97±0.82, 3.24±0.75, and 4.47±0.60. SNR, CNR and subjective scores had significant difference among groups (all p<0.001). The optimal keV monochromatic images were superior to the 70keV monochromatic and 140kVp polychromatic images, and there was high agreement between the two observers on image quality score (kappa>0.80). CONCLUSIONS Virtual monochromatic images at approximately 63keV in dual-energy spectral CT pulmonary angiography yielded the best CNR and highest diagnostic confidence for imaging bronchial arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

BACKGROUND The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. METHODS The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all partici...

متن کامل

Spectral CT in the Demonstration of the Pancreatic Arteries and Their Branches: A Comparison With Conventional CT

The aim of this study was to investigate the performance of monochromatic images of spectral computed tomographic (CT) in the visualization of the pancreatic arteries compared with polychromatic CT images. We conducted a case-control study in a group of 26 consecutive patients with monochromatic CT and contrasted the results against a control group of 26 consecutive patients with polychromatic ...

متن کامل

Improving the quality of images synthesized by discrete cosines transform – regression based method using principle component analysis

  Purpose: Different views of an individuals’ image may be required for proper face recognition.   Recently, discrete cosines transform (DCT) based method has been used to synthesize virtual   views of an image using only one frontal image. In this work the performance of two different   algorithms was examined to produce virtual views of one frontal image.   Materials and Methods: Two new meth...

متن کامل

Optimization of the monochromatic energy in imaging the celiac artery with dual energy spectral CT angiography

To identify the optimal monochromatic energy of the dual energy spectral CT Angiography (CTA) of celiac artery with high image quality. 32 patients were tested by the contrast-enhanced CT with the dual energy spectral imaging mode. Based on the polychromatic data, images of celiac artery were reconstructed at the optimal monochromatic energy, 70 keV monochromatic energy level and the 140 kVp tu...

متن کامل

Spectral CT Imaging of Laryngeal and Hypopharyngeal Squamous Cell Carcinoma: Evaluation of Image Quality and Status of Lymph Nodes

PURPOSE The purpose of this study was to evaluate image quality and status of lymph nodes in laryngeal and hypopharyngeal squamous cell carcinoma (SCC) patients using spectral CT imaging. MATERIALS AND METHODS Thirty-eight patients with laryngeal and hypopharyngeal SCCs were scanned with spectral CT mode in venous phase. The conventional 140-kVp polychromatic images and one hundred and one se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016