Is miniscrew primary stability influenced by bone density?

نویسندگان

  • Mariana Marquezan
  • Margareth Maria Gomes de Souza
  • Mônica Tirre de Souza Araújo
  • Lincoln Issamu Nojima
  • Matilde da Cunha Gonçalves Nojima
چکیده

Primary stability is absence of mobility in the bone bed after mini-implant placement and depends on bone quality among other factors. Bone quality is a subjective term frequently considered as bone density. The aim of this preliminary study was to evaluate bone density in two bovine pelvic regions and verify the primary stability of miniscrews inserted into them. Forty bone blocks were extracted from bovine pelvic bones, 20 from iliac and 20 from pubic bone, all of them containing cortical bone about 1 mm thick. Half of the sections extracted from each bone were designated for histological evaluation of bone density (trabecular bone area - TBA) and the other half for bone mineral density (BMD) evaluation by means of central dual-energy X-ray absorptiometry (DEXA). Then, twenty self-drilling miniscrews (INP®, São Paulo, Brazil) 1.4 mm in diameter and 6 mm long were inserted into the bone blocks used for BMD evaluation. Peak implant insertion torque (IT) and pull-out strength (PS) were used for primary stability evaluation. It was found that iliac and pubic bones present different bone densities, iliac bone being less dense considering BMD and TBA values (P > 0.05). However, the miniscrew primary stability was not different when varying the bone type (P < 0.05). IT and PS were not influenced by these differences in bone density when cortical thickness was about 1 mm thick.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study

BACKGROUND Stability is determined as one of the requirements in use of Temporary Anchorage Devices (TAD) in orthodontics. Miniscrew has been a widely used Bone Anchor. Compared with mini-implant that necessitates osseointegration; mechanical retention is a determining factor for primary stability of miniscrew. Studies investigated various ways to increase primary stability. The aim of this stu...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

Effect of immediate loading on the biomechanical properties of bone surrounding the miniscrew implants.

The aim of this study was to investigate the effect of immediate loading on the biomechanical properties of bone surrounding a miniscrew implant. Forty titanium alloy miniscrew implants were placed on the buccal side of the maxillae and mandibles in four beagle dogs. Twelve pairs of miniscrew implants were immediately loaded with approximately 150 g of continuous force using nickel-titanium coi...

متن کامل

Effect of force on alveolar bone surrounding miniscrew implants: a 3-dimensional microcomputed tomography study.

INTRODUCTION The primary aim of this study was to better understand how bone adapts to forces applied to miniscrew implants. A secondary aim was to determine whether the direction of force applied to miniscrew implants has an effect on bone surrounding the miniscrew implants. METHODS A randomized split-mouth design, applied to 6 skeletally mature male foxhound dogs, was used to compare minisc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 2011