Three Level Inverter Based Shunt Active Power Filter Using Multi-Level Hysteresis Band Current Controller

نویسندگان

  • Ferhat UCAR
  • Resul COTELI
  • Besir DANDIL
چکیده

In this paper, a three-level inverter based Shunt Active Power Filter (SAPF) using Multi-Level Hysteresis Current Controller (MLHCC) is presented for solution of power quality problems in distribution system. A simulation model of SAPF is prepared in Matlab/Simulink environment. MLHCC is used for control of SAPF currents. In simulation study, it is considered that SAPF executes two tasks covering compensation of harmonics and reactive power. Therefore, control algorithm is formed to execute two tasks. The Synchronous Reference Frame Method (SRFM) is used to extract the reference currents. Dynamic performance of SAPF is evaluated using two nonlinear loads switched at different times. Some simulation results are given to show performance of a three-level inverter based SAPF using MLHCC. Simulation results show that current harmonics has been kept inside specific recommendation of IEEE-519 and ac grid is approximately kept in unity power factor. Streszczenie. W artykule przedstawiono bocznikowy aktywny filtr mocy (ang. Shunt Active Power Filter) z trójpoziomowym falownikiem. Sterowanie oparte zostało na wielopoziomowym regulatorze histerezowym prądu (ang. Multi-Level Hysteresis Current Controller). Filtr aktywny spełnia rolę kompensatora wyższych harmonicznych oraz mocy biernej. (Sterowanie bocznikowego aktywnego filtru mocy z przekształtnikiem trójpoziomowym oparte na wielopoziomowym regulatorze histerezowym prądu)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi Band Hysteresis Current Controlled Flying Capacitor Multi Level Inverter Based Shunt Active Power Filter for Distribution Systems

Lecturer, Department Of Electrical Engineering, L. E. College Morbi-363642, India, ---------------------------------------------------------------------***--------------------------------------------------------------------Abstract -This paper presents application of flying capacitor multi level inverter in high voltage shunt active power filter. The proposed strategy uses three independent mul...

متن کامل

An adaptive hysteresis band current controller for shunt active power filter

In this paper, an adaptive hysteresis band current controller is proposed for active power filter to eliminate harmonics and to compensate the reactive power of three-phase rectifier. The adaptive hysteresis band current controller, proposed by Bose [An adaptive hysteresis band current control technique of a voltage feed PWM inverter for machine drive system, IEEE Trans. Ind. Electron. 37 (5) (...

متن کامل

Performance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

متن کامل

Fuzzy Based Hysteresis Band Limit Controlled Active Power Filter for Non Linear Loads

This paper presents a hysteresis band control for achieving maximum benefits from these gridinterfacing inverters when installed in 3-phase 4-wire distribution systems. The inverter is controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1) power converter to inject power generated from RES to the grid, and 2)...

متن کامل

Comparative Analysis between PI and Fuzzy Controllers for Dc Voltage Control of Unbalanced 4 Wire Shunt Active Power Filter

This research proposes a shunt active power filter (SAPF) for harmonics mitigation in order to improve power quality of the electrical network. The reference harmonic current extraction technique used was based on DQ0 power theory under unbalanced non-linear loads conditions for four wire-installed systems. The DC-link voltage plays an important role in SAPF design to guarantee both steady high...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012