Evaluation of BioVue Column Agglutination Technology for quality control purpose of therapeutic anti-Rh immunoglobulin preparations

نویسنده

  • Essam H. Ibrahim
چکیده

Anti-D immunoglobulin; BioVue column agglutination test; Quality control; Haemolytic disease; Anti-Rh(D) titration; Rh-factor Abstract The preparation anti-D immunoglobulin is an important therapy for both treatment and protection. Titer of anti-D immunoglobulin preparation is an important factor to determine the dose of treatment. Many methods are used to evaluate the titer of anti-D immunoglobulin preparation. One of the new methods developed recently is column agglutination test. To evaluate the BioVue column agglutination test, it was compared to conventional tube agglutination test using anti-D immunoglobulin preparations from three different producers, ten lots each. Results showed that the BioVue column agglutination test is comparable to conventional tube agglutination test but with much ease. In conclusion, the BioVue column agglutination test is accurate and easy to use in determination of anti-D titer for quality control purposes. a 2010 King Saud University. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Anti-Rh D Immunoglobulin Stability in the Lyophilization Processes

Objective Anti-Rh D IgG is used for the prevention of anti-D antibody production in Rh- individuals who have been exposed to Rh+ red blood cells. The stability of IgG preparations as a solution is low, with a shelf life of a year or more. Formulation of anti-Rh D IgG as a lyophilized preparation would decrease its degradation rate and increases its shelf life. The objective of this study was t...

متن کامل

Immunologic Basis and Immunoprophy-laxis of RhD Induced Hemolytic Disease of the Newborn (HDN)

RhD antigen is the most immunogenic and clinically significant antigen of red blood cells after ABO system. It has historically been associated with hemolytic disease of the newborn (HDN) which is now routinely prevented by the administration of polyclonal anti-D immunoglobulin. This management of HDN has proven to be one of the most successful cases of prophylactic treatment based on antibody ...

متن کامل

SENSITIBITY OF VARIOUS METHODS IN THE DETECTION OF IgG ANTIBODIES TO RED CELL ANTIGENS

In recent years, new methods such as microtube column agglutination methods and microplate methods using automated instruments have been used for blood typing, antibody screening testing and crossmatching testing. However, no precise comparison study of the performance of these methods and conventional tube methods has been done. In the present study, we performed a comparison study on sensitiv...

متن کامل

Anti-H Antibody Showing Agglutination in the Anti-Human Globulin Phase in a Korean Patient

Dear Editor, Anti-H antibody is a type of anti-red blood cell (RBC) antibody that agglutinates with H antigen, which is universally present on human RBCs. The most widely known problem related to the anti-H antibody is the potentially lethal hemolytic transfusion reaction seen in individuals with the Bombay O blood type [1-3]. Other anti-H antibodies are mostly found in A1 or A1B blood type ind...

متن کامل

Production, quality control and biological evaluation of 153Sm-EDTMP in wild-type rodents

  Introduction: Nowadays various bone pain palliative therapeutic agents have been developed for bone metastases. Among those, 153Sm-ethylenediamine tetramethylene phosphonic acid (153Sm-EDTMP) is the major therapeutic agent which is widely used in the world. In this study, production, quality control and biodistribution studies of this therapeut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015