Diathermy-induced ventricular fibrillation with Riata high-voltage lead insulation failure.

نویسندگان

  • Prasad Gunaruwan
  • Malcolm Barlow
چکیده

A 76-year-old man presented after a series of six shocks in quick succession from his implanted biventricular defibrillator, without relief of palpitations and pre-syncope. Initial 12-lead electrocardiogram revealed ventricular tachycardia at 180 b.p.m. One 200 J external shock was delivered with successful return to sinus rhythm. Interrogation of the device revealed that the device had been reset. Neither the episodes nor the therapies delivered were accessible. The patient was taken to the cardiac catheterization lab for a replacement. During dissection to free the leads ventricular fibrillation was noted immediately following diathermy application. Three external 200 J shocks were required to return to sinus rhythm. Further dissection without diathermy revealed a clear insulation failure of the high-voltage lead (Figure 1). To the best of our knowledge diathermyinduced ventricular fibrillation, as a result of insulation failure, has not been reported previously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shock-induced right ventricular pacing failure caused by a short circuit: Uncommon but life-threatening complication of the Riata lead

Introduction The Riata and Riata ST implantable cardioverter-defibrillator (ICD) leads, a narrow caliber silicone lead without an outer jacket, have been shown to be prone to structural and electrical failure. While much interest has been shown in potentially lethal high-voltage (HV) failures caused by electrical short circuits due to a breach in the ethylene tetrafluoroethylene (ETFE) insulati...

متن کامل

A Case of Riata® Dual Coil Defibrillator Lead Failure in a Patient with Ventricular Fibrillation

A 50-year-old man, who underwent a procedure for an implantable cardioverter defibrillator (ICD), visited the outpatient department of our clinic after suffering multiple ICD shocks. The ICD interrogation revealed recurrent shock due to a high frequency of noise that is sensed by the device as ventricular fibrillation. Chest radiography revealed a significant split in the insulation of the lead...

متن کامل

Externalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation

QuickSite (St Jude Medical, Sylmar, CA, USA) is a silicone and polyurethane-insulated coronary sinus pacing lead. Riata lead (St Jude Medical, Sylmar, CA, USA) is a silicone insulated right ventricular shock lead. Recently, insulation breach of silicone based leads raised a huge concern. Fluoroscopic examination of these two leads in the same patient revealed externalization of these two leads....

متن کامل

Fluoroscopic investigation of Riata® transvenous defibrillator leads.

BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...

متن کامل

Long-term performance of the St Jude Riata 1580-1582 ICD lead family.

OBJECTIVE Safety concerns about the Riata ICD shock lead were recently raised, with insulation failure due to conductor externalisation. Its incidence and presentation were assessed, and predictors of insulation failure and lead survival of the Riata 1580-1582 were studied, retrospectively, before the official recall. METHODS All 374 patients at the Erasmus Medical Center between July 2003 an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2013