Radiation Safety Assessment of the New Neutron Radiography System at Tehran Research Reactor

نویسندگان

چکیده مقاله:

Recently, a new Neutron Radiography (NR) beam line has been designed, constricted, installed and tested based on the use of E-beam tube of Tehran Research Reactor (TRR). Initial tests have been shown that the system can be used for different samples and purposes such as nuclear plates and rods fuels.  For this end the system need a suitable irradiation room which should be installed at the NR beam port. The present work is the analyses of the proposed irradiation room in view of irradiation safety. To do this, using MCNPX Monte Carlo code the proposed room structure and neutron beam catcher have been simulated and then neutron/gamma dose have been calculated at different locations around the room walls. The results show that the designed room and beam catcher have good performance in case of reduce the total neutron and gamma dose to 10 μSv/h which is desired value in view of radiation protection issue.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of neutron radiography in the MNSR Low Power Research Reactor

Neutron radiography is an unique, advanced and useful non-destructive test method in various industries and researches. Nuclear reactors are powerful and stable neutron sources for the neutron radiography system. In this research, the MNSR research reactor has been used as a neutron source for a neutron radiography system, and its neutron beam parameters have been evaluated. Also, using the dir...

متن کامل

Real-Time Neutron Radiography at the IEA-R1m Nuclear Research Reactor

A LIXI(Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1m nuclear research reactor of the IPEN-CNEN/SP has been opti...

متن کامل

Calculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom

In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...

متن کامل

Assessment of compliance to radiation safety and protection at the radiology department

Background: Several potential challenges with radiation protection (RP) and safety culture in radiology departments need to be addressed. This study assesses radiographers’ adherence to radiation protection practices in radiology departments. Materials and Methods: A cross-sectional study was conducted among radiographers; 210 self-administrated questionnaires were sent to the participants. An ...

متن کامل

conditional copula-garch methods for value at risk of portfolio: the case of tehran stock exchange market

ارزش در معرض ریسک یکی از مهمترین معیارهای اندازه گیری ریسک در بنگاه های اقتصادی می باشد. برآورد دقیق ارزش در معرض ریسک موضوع بسیارمهمی می باشد و انحراف از آن می تواند موجب ورشکستگی و یا عدم تخصیص بهینه منابع یک بنگاه گردد. هدف اصلی این مطالعه بررسی کارایی روش copula-garch شرطی در برآورد ارزش در معرض ریسک پرتفویی متشکل از دو سهام می باشد و ارزش در معرض ریسک بدست آمده با روشهای سنتی برآورد ارزش د...

Collimator Design for Neutron Radiography Systems Using a Reactor Flux

This paper is aimed to investigate the design of an optimized neutron radiography system that utilizes the flux of a reactor. Moderation, collimation aspects are studied. A Monte Carlo code, MCNP4C, was utilized to achieve a maximum and more homogenous neutron flux in the collimator outlet next to the image plane, taking into account geometric characteristics. It was possible to obtain a normal...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  251- 256

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023