γ-Ray Induced Vapor-phase Graft-polymerization of Methyl Methacrylate onto Poly(propylene)

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic Study of Graft Polymerization of Acrylic Acid and Ethyl Methacrylate onto Starch by Ceric Ammonium Nitrate

Graft polymerization of acrylic acid (AA) and ethyl methacrylate (EMA) onto starch (St) were carried out in aqueous solution using ceric ammonium nitrate (CAN) as redox system under N2 atmosphere. The effect of pH, reaction time, temperature, concentrations of CAN, St, and monomers on the graft yield was investigated. Monomer reactivity was in the following order: AA>EMA.<em...

متن کامل

Preparation of polymer decorated graphene oxide by γ-ray induced graft polymerization.

Herein, we report a facile approach to decorate graphene oxide (GO) sheets with poly(vinyl acetate) (PVAc) by γ-ray irradiation-induced graft polymerization. The content of PVAc in the obtained sample, i.e., PVAc grafted GO (GO-g-PVAc) is calculated by the loss weight in thermogravimetric analysis (TGA) curves. A GO-g-PVAc sample with a degree of grafting (DG) of 28.5% was well dispersed in com...

متن کامل

Graft Polymerization of Acrylonitrile onto Wheat Straw

Acrylonitrile was graft polymerized onto ground, water-washed wheat straw using Fe2 +-H 20 2 as initiator. Reaction conditions were selected to minimize homopolymer formation and ma.xi.mize the amount of polyacrylonitrile (PAN) grafted to straw. Polymerizations typically yielded straw-g-PAN containing 30-35% PAN. A two-step fractionation scheme was developed for determining the relative amounts...

متن کامل

Graft Copolymerization of Methyl Methacrylate onto Cellulose in Homogeneous Medium – Effect of Solvent and Initiator

Homogeneous graft copolymerization of methyl methacrylate (MMA) onto cellulose was carried out in N, N – dimethyl acetamide/LiCl (DMAc/LiCl) and dimethyl sulfoxide/ paraformaldehyde (DMSO/PF) solvent system taking ceric ammonium nitrate (CAN), benzoyl peroxide (BPO) and tin (II)-2ethyl hexanoate [Sn(Oct)2] as initiators. Different grafting parameters like graft yield (GY), grafting efficiency (...

متن کامل

X-ray spectromicroscopy study of competitive adsorption of protein and peptide onto polystyrene-poly(methyl methacrylate).

A synchrotron-based x-ray photoemission electron microscope (X-PEEM) was used to investigate the coadsorption of a mixture of human albumin serum and SUB-6, a synthetic antimicrobial peptide, to a phase-segregated polystyrene/poly(methyl methacrylate) (PMMA) substrate at varying concentrations and pH. The authors show that X-PEEM could detect the peptide adsorbed from solution at concentrations...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: NIPPON KAGAKU KAISHI

سال: 1972

ISSN: 2185-0925,0369-4577

DOI: 10.1246/nikkashi.1972.1938