1586 PLASMA CREATININE (Per) IN CHILDREN: INTERLABORATORY VARIATION
نویسندگان
چکیده
منابع مشابه
Calculation of creatinine clearance from plasma creatinine.
Glomerular filtration rate (GFR) is commonly assessed by measurement of endogenous creatinine clearance (Ccr). Several formulae have been described to calculate Ccr from plasma creatinine. I have evaluated the effectiveness of four formulae in 35 healthy subjects (21M and 14F, 18-34 years) and in 41 patients (24M, 17F, 20-69 years) attending a renal clinic with diminished renal function (serum ...
متن کاملSimple estimate of creatinine clearance from plasma creatinine in neonates.
Thirteen newborn infants, 8 preterm and 5 term, with either mild or serious neonatal asphyxia were studied. From the first 24 hours of life to day 13, glomerular filtration rate (GFR) estimated by creatinine clearance was compared with the values obtained using Schwartz's formula: GFR (ml/min per 1.73 m2) = 0.55 x length (cm)/plasma creatinine (mg/100 ml). Both in term and preterm infants, valu...
متن کاملInterlaboratory variation of plasma total homocysteine measurements: results of three successive homocysteine proficiency testing surveys.
BACKGROUND Numerous studies have demonstrated that increased plasma total homocysteine (tHcy), whether measured after fasting or after a methionine load, is associated with increased risk for cardiovascular and thromboembolic diseases. However, little information is available regarding interlaboratory variation of tHcy measurements, especially at the increased tHcy concentrations observed after...
متن کاملGenis , Planning Resources 1586
Thank you for the opportunity to comment upon the Preliminary Draft Amendments to the Guidelines for the Implementation of the California Environmental quality Act (CEQA)(Title 14, California Code of Regulations). The Amendments are proposed in order to implement Senate Bill 97 (Dutton), which directs the Governor’s Office of Planning and Research (OPR) to develop guidelines for the mitigation ...
متن کاملPlasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories
BACKGROUND There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pediatric Research
سال: 1985
ISSN: 0031-3998,1530-0447
DOI: 10.1203/00006450-198504000-01610