2177) Experimental Study on Steel Beam-to-Column Connection with Openings Subjected to Lateral Load

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite element analysis of a rigid beam to column connection reinforced with channels

Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...

متن کامل

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Centrifuge modelling of long piles subjected to lateral loading with high load eccentricity in sand

In this research paper, five centrifuge lateral loading tests of long piles with a considerable load eccentricity were carried out in the sand to investigate the impacts of the load eccentricity and pile length changes on the lateral behavior of a flexible pile beside the determination of experimental p-y curves. Comparing experimental test results with the recommended API (American Petroleum ...

متن کامل

Ultimate Load Capacity and Behavior of Thin-Walled Curved-Steel Square Struts, Subjected to Compressive Load

There have been some experimental tests on hollow curved-steel struts with thin-walled square sections, in order to investigate their general behavior, particularly their capacity for bearing differing loads. One set of square tubes are cold-formed into segments of circular arcs with curvature radii, equal to 4000 mm. Different lengths of curved struts are fabricated so as to cover a practical ...

متن کامل

Damage Avoidance Design Steel Beam-Column Moment Connection Using High-Force-To-Volume Dissipators

Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beamcolumn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Transactions of the Architectural Institute of Japan Summaries of Technical Papers

سال: 1965

ISSN: 2433-0035

DOI: 10.3130/aijsaxxe.40.0_289