255 MEASUREMENT OF CEREBRAL VENOUS SATURATION BY NEAR INFRARED ABSORPTION SPECTROSCOPY

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of oxygen saturation in venous blood by dynamic near infrared spectroscopy.

A method for the measurement of oxygen saturation in the venous blood, SvO2, based on optical measurements of light absorption in the infrared region is presented. The method consists of applying relatively low external pressure of 25 mm Hg on the forearm, thereby increasing the venous blood volume in the tissue, and comparing the light absorption before and after the external pressure applicat...

متن کامل

Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation.

Near-infrared spectroscopy (NIRS) is a noninvasive optical technique to monitor cerebral oxygen saturation at the bedside. Despite its applicability, NIRS has had limited clinical use because of concerns about accuracy, noted by intersubject variability in slope and intercept of the line between NIRS- and weighted-average arterial-cerebrovenous saturation (SMO2). This study evaluated transcrani...

متن کامل

Reproducibility of cerebral tissue oxygen saturation measurements by near-infrared spectroscopy in newborn infants.

Early detection of cerebral hypoxemia is an important aim in neonatology. A relevant parameter to assess brain oxygenation may be the cerebral tissue oxygen saturation (StO(2)) measured by near-infrared spectroscopy (NIRS). So far the reproducibility of StO(2) measurements was too low for clinical application, probably due to inhomogeneities. The aim of this study was to test a novel sensor geo...

متن کامل

Changes in task-associated cerebral blood induced by role lettering: measurement by multichannel near-infrared spectroscopy.

Using optical topography (near-infrared spectroscopy: NIRS), relative changes in oxidized hemoglobin (oxy-Hb) were measured before and after the introduction of Role lettering. Tasks performed during measurements included antegrade (from the subject to other persons) and retrograde (from other persons to the subject) mental imaging and writing tasks. All subjects were junior high school student...

متن کامل

Measuring moisture in cheese by near infrared absorption spectroscopy.

Data in the literature indicate that the measurement of moisture in cheese by near infrared transmittance (NIT) is more accurate than by reflectance (NIR). The accuracy of the NIT measurement (SEP) was calculated for Edam, Gouda, Brie, Colby, and Cheddar. A range of SEP values (0.12-0.35) was obtained using different methods of calibration for different types of samples. There was close agreeme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pediatric Research

سال: 1994

ISSN: 0031-3998,1530-0447

DOI: 10.1203/00006450-199407000-00255