3408Lead material retention and clinical outcomes in patients undergoing transvenous lead extraction
نویسندگان
چکیده
منابع مشابه
Safety and effectiveness of transvenous lead extraction in elderly patients.
BACKGROUND There is a considerable controversy regarding safety of transvenous lead extraction (TLE) in elderly patients due to their potentially worse general condition, more concomitant diseases, more difficult sedation or analgesia. Moreover, the present experience is not relevant. The aim of the study was the comparison of safety and feasibility of TLE in elderly and middle-aged patients. ...
متن کاملLong-term mortality after transvenous lead extraction.
BACKGROUND The number of cardiovascular implantable electronic devices has increased progressively and has led to an increased need for transvenous lead extraction (TLE). Multiple reports of TLE procedural outcomes exist; however, data regarding postprocedural and long-term mortality are limited. METHODS AND RESULTS We performed a retrospective study of consecutive patients undergoing TLE at ...
متن کاملSnare sheath versus evolution sheath in transvenous lead extraction.
Lead extraction remains a challenging procedure with significant success. Owing to the increasing use of cardiac implantable electronic devices, there is a growing need for effective techniques management, to avoid the occurrence of device-related complications and lead dysfunction. We made a comparison of Evolution sheath and Needles Eye Snare sheath (abbreviated to Snare sheath) by analyzed t...
متن کاملOutcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves.
BACKGROUND Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. METHODS AND RESULTS We retrospectively screened 794 transvenous lead e...
متن کاملSuccessful transvenous lead extraction after a failed open surgical attempt.
An 81-year-old man was referred with an infected cardiac resynchronization therapy defibrillator (CRT-D) system. His initial dualchamber implantable cardioverter-defibrillator (ICD) had been implanted 8 years earlier and upgraded to a CRT-D system 2 years before referral. Epicardial atrial and left ventricular (LV) leads were subsequently added after the endocardial LV lead lost capture. The en...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Heart Journal
سال: 2018
ISSN: 0195-668X,1522-9645
DOI: 10.1093/eurheartj/ehy563.3408