3D Electrical Impedance Tomography reconstructions from simulated electrode data using direct inversion $ \mathbf{t}^{\rm{{\textbf{exp}}}} $ and Calderón methods

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On a Calderón Problem in Frequency Differential Electrical Impedance Tomography

Recent research in electrical impedance tomography produce images of biological tissue from frequency differential boundary voltages and corresponding currents. Physically one is to recover the electrical conductivity σ and permittivity ε from the frequency differential boundary data. Let γ = σ+iωε denote the complex admittivity, Λγ be the corresponding Dirichlet-to-Neumann map, and dΛγ dω ∣∣∣ ...

متن کامل

Accounting for erroneous electrode data in electrical impedance tomography.

An unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper develops an image reconstruction methodology which allows use of the remaining valid data. A finite element model of the EIT difference imaging forward problem is linearized as z = Hx, where z ...

متن کامل

Multi-electrode systems for electrical impedance tomography.

A wide range of electrode system designs is reviewed for their possible use in UT

متن کامل

Active Electrode Based Electrical Impedance Tomography System

Abstract: EIT can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key di culties in EIT instrumentation make such monitoring di cult: 1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, and 2) EIT electrodes are di c...

متن کامل

Electrical impedance tomography in 3D using two electrode planes: characterization and evaluation.

Electrical impedance tomography (EIT) uses body surface electrical stimulation and measurements to create conductivity images; it shows promise as a non-invasive technology to monitor the distribution of lung ventilation. Most applications of EIT have placed electrodes in a 2D ring around the thorax, and thus produced 2D cross-sectional images. These images are unable to distinguish out-of-plan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Inverse Problems & Imaging

سال: 2021

ISSN: 1930-8345

DOI: 10.3934/ipi.2021032