3D peripheral subtraction MRA using flow-spoiled ECG-triggered balanced SSFP

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible phase-encoding in 3D coronary MRA with balanced SSFP

Fig. 3. Comparison of PE schemes in bSSFP CMRA of the right coronary artery. Conspicuity of the distal RCA was good in all three schemes. Fig. 2. Flexible PE schemes with partial Fourier acquisition in the PE (kY) dimension and k-space corners removed from sampling, colorized from red to blue to reflect the sequence of acquisition. Plots of the first and last acquisition trains are shown, refle...

متن کامل

Nonenhanced Renal MRA using Time-SLIP with 3D balanced SSFP: Optimization of Coronal Acquisition

PURPOSE Recent association report of gadolinium contrast agents and Nephrogenic Systemic Fibrosis (NSF) diseases makes it increasing interests in using non-contrast MRA technique as an alternative [1]. Nonenhanced renal 3D MRA using time-spatial labeling inversion pulse (time-SLIP) with respiratory triggering has been optimized using the inflow technique in the axial acquisition [2,3]. However,...

متن کامل

3D Non-Contrast MRA of Lower Extremities Using Balanced SSFP with Flow-Sensitive Dephasing (FSD) at 3T

H. GUO, I. ATANASOVA, R. P. LIM, P. STOREY, J. XU, Q. CHEN, H. RUSINEK, Z. FAN, D. LI, AND V. S. LEE DEPARTMENT OF RADIOLOGY, NEW YORK UNIVERSITY SCHOOL OF MEDICINE, NEW YORK, NY, UNITED STATES, COLUMBIA UNIVERSITY, NEW YORK, NY, UNITED STATES, SIEMENS MEDICAL SOLUTIONS USA, INC., MR R&D COLLABORATION, NEW YORK, UNITED STATES, DEPARTMENTS OF RADIOLOGY AND BIOMEDICAL ENGINEERING, NORTHWESTERN UN...

متن کامل

Single breathhold 3D balanced SSFP coronary MRA at 3.0T: a reproducibility study

Background Balanced steady-state free precession (bSSFP) imaging [1] has developed as the method of choice for coronary MRA at 1.5T. The bSSFP acquisition, however, is especially susceptible to static magnetic field (B0) inhomogeneities and radio frequency transmit field (B1+) distortions, both of which are more pronounced at higher field strengths, resulting in degraded and variable image qual...

متن کامل

Flow quantification in the heart chambers: 3D PC-SSFP compared with spoiled GE

Introduction: Flow quantification through the valves is of major importance in patients with valvular heart disease. Using a 3D MRI acquisition, the mitral valve can be imaged during the whole cardiac cycle, for direct quantification of flow through the valve. So far, 3D phase contrast (PC) for velocity quantification is only implemented in a spoiled Gradient Echo (GE) sequence. However, PC-GE ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance

سال: 2009

ISSN: 1532-429X

DOI: 10.1186/1532-429x-11-s1-p288