Fast Spin Echo Imaging
In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...
متن کاملInteractive fast spin-echo imaging.
It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given ...
متن کاملComparison of Fast Recovery Fast Spin Echo and Conventional Fast Spin Echo for T2 Weighted Imaging of the Prostate Gland
Introduction The FRFSE sequence is a modification to the standard FSE sequence in which additional RF pulses are used to accelerate recovery of longitudinal magnetization after the echo train is acquired. The sequence can provide enhanced fluid signal in the setting of short TR for joint imaging. We compared this sequence to standard FSE using a long TR for axial endorectal coil T2 weighted ima...
متن کاملFast Spin- Echo
Imaging with T2-weighting is prescribed in nearly every diagnostic imaging protocol, owing to the fact that in many pathologic states, diseased tissue may be distinguished from normal tissue through apparent differences in T2. Conventional T2-weighted imaging carries with it a heavy time cost, however, as a relatively long time must be allowed between acquisitions in order to allow T1 recovery ...
متن کاملFast spin-echo imaging in the evaluation of intradural disease of the spine.
PURPOSE Fast spin echo (FSE) images were compared with conventional images in 46 patients with intradural spinal disease to determine their accuracy in the detection and delineation of lesions. MATERIALS AND METHODS The images were interpreted by two neuroradiologists, who read individually. A total of 720 blinded readings formed the basis for this evaluation. A gold standard for each patient...