58. Improved ^<201>Tl Myocardial SPECT Imaging Using Energy-Weighted Acquisition Method
نویسندگان
چکیده
منابع مشابه
Improved susceptibility weighted imaging method using multi-echo acquisition.
PURPOSE To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in...
متن کاملCompensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...
متن کاملMyocardial perfusion imaging with 201Tl.
The object of this review is to provide information about (201)Tl-thallous chloride in radionuclide myocardial perfusion imaging. This technique has experienced a recent resurgence because of the shortage of (99m)Tc. After reading this article, the technologist will be able to describe the properties and uptake mechanism of (201)Tl, the procedure for myocardial perfusion imaging with this agent...
متن کاملcompensation of cross-contamination in simultaneous 201tl/99mtc myocardial perfusion spect imaging
introduction: it is a common protocol to use 201tl for the rest and 99mtc for the stress cardiac spect imaging. theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. however, a potential limitation is the cross-contamination of scattered photons from 99mtc and collimator x-rays into the 201tl energy window. we used a middle en...
متن کاملOptimized energy window configuration for 201Tl imaging.
UNLABELLED A poor signal-to-noise ratio attributable to a low injected dose of thallium and the presence of scattered photons are the major impediments in the use of thallium as an imaging agent. Thallium decays in a complicated way and emits photons in a wide range of energies (68-82 keV). To increase the ratios of primary photons to scatter photons (primary-to-scatter ratios) and possibly inc...