A 15 BIT THIRD ORDER POWER OPTIMIZED CONTINUOUS TIME SIGMA DELTA MODULATOR FOR AUDIO APPLICATIONS
نویسندگان
چکیده
منابع مشابه
Design of a 3rd Order 1.5-Bit Continuous-Time Fully Differential Sigma-Delta (ΣΔ) Modulator Optimized for a Class D Audio Amplifier Using Differential Pairs
This paper presents a 3 order 1.5-bit Continuous-Time Fully Differential Ʃ∆ modulator with distributed feedback for a class D audio amplifier, using BJT differential pairs to implement the integrator stages. By relying on simple gain blocks instead of operational amplifiers to build the loop filter, a simpler overall circuit is obtained, where the non-ideal effects are embedded in the loop filt...
متن کاملA Wideband Low - Power Continuous - Time Delta - Sigma Modulator for Next Generation Wireless Applications by
approved:
متن کاملConcept for a 12-bit Digital Bandpass Delta-Sigma Modulator for Power Amplifier Applications
A digital bandpass delta-sigma modulator (BPDSM) with an SNR of 74 dB at a bandwidth of 20 MHz is proposed. A time-interleaved structure and optimized sparse-tree adders ensure a high sampling frequency and thus a high input signal frequency range. The concept is based on static CMOS gates using a commercial 65 nm process. Simulations indicate a sampling frequency up to 6.6 GHz and a signal fre...
متن کاملContinuous-Time Delta-Sigma Modulator Model for A/D Conversion
In this paper we present a study of a Continuous-Time Delta-Sigma Modulator (CT ∆ΣM) to be applied in radio communication systems, including a high-level modelization for simulation purposes. The conventional sample-and-hold and comparator blocks, very popular in CT ∆ΣM models, are replaced by an analog-to-digital converter (ADC), in order to allow the ADC modelization. In this way, we propose ...
متن کاملVery Low Power Sigma Delta Modulator for Biomedical Applications
This paper discusses the design of picowatt power Sigma-delta modulator with genetic algorithm (GA) based oversampling technology. This Sigma-delta modulator design is paid special attention to its low power application of portable electronic system in digitizing biomedical signals such as Electro-cardiogram (ECG), Electroencephalogram (EEG) etc. [1]. A high performance, low power second order ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2014
ISSN: 2321-7308,2319-1163
DOI: 10.15623/ijret.2014.0327019