A Braille Reading System Based on Electrotactile Display With Flexible Electrode Array
نویسندگان
چکیده
Due to visual impairment and lack of social attention, the reading problem blind has not been well resolved. Many existing Braille devices still have many problems are accepted by public. This paper developed a portable system based on electrotactile display technology. The proposed is composed six-channel stimulator, flexible electrode array for graphical user interface (GUI) monitoring control. Based flexibility system, two strategies designed: spatial mode sequential mode. was preliminary tested six sighted subjects. results showed that subjects were able recognize characters with more than 80% accuracy within less 10 seconds initial use. Compared systems, this portable, wearable in
منابع مشابه
Wireless sEMG System with a Microneedle-Based High-Density Electrode Array on a Flexible Substrate
Surface electromyography (sEMG) signals reflect muscle contraction and hence, can provide information regarding a user's movement intention. High-density sEMG systems have been proposed to measure muscle activity in small areas and to estimate complex motion using spatial patterns. However, conventional systems based on wet electrodes have several limitations. For example, the electrolyte enclo...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملflexible electrode array for retinal stimulation
in this work, ito/pet (indium tin oxide / polyethylene terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. flexible ito/pet implantable electrode array for a retina has been developed. the electrode array is fabricated on a thin pet/ito substrate and is encapsulated using, su-8, an insulating material. pet substrate and su-8 po...
متن کاملA MEMS-based flexible multichannel ECoG-electrode array.
We present a micromachined 252-channel ECoG (electrocorticogram)-electrode array, which is made of a thin polyimide foil substrate enclosing sputtered platinum electrode sites and conductor paths. The array subtends an area of approximately 35 mm by 60 mm and is designed to cover large parts of a hemisphere of a macaque monkey's cortex. Eight omnetics connectors are directly soldered to the foi...
متن کاملReading Visual Braille with a Retinal Prosthesis
Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE/CAA Journal of Automatica Sinica
سال: 2022
ISSN: ['2329-9274', '2329-9266']
DOI: https://doi.org/10.1109/jas.2022.105476