A Calibrating Six-Port Compact Circuit using a New Technique Program
نویسندگان
چکیده
منابع مشابه
New Structure for a Six-Port Reflectometer in Monolithic Microwave Integrated-Circuit Technology
This paper presents a new structure for a six-port reflectometer which due to its simplicity can be implemented very easily in monolithic microwave integrated-circuit (MMIC) technology. It uses nonmatched diode detectors with a high input impedance which are placed around a phase shifter in conjunction with a power divider for the reference detector. The circuit has been fabricated using the F2...
متن کاملSix-port Measurement Technique: Principles, Impact, Applications
The paper reviews the development of the six-port measurement technique since the time it was introduced in 1977 until present days. Working principles of six-port reflectometer and six-port network analyzer are explained. The technique is put in context with other scattering parameter measurement principles; the advantages and drawbacks are discussed. Some typical SPR implementations are prese...
متن کاملTwo-port laparoscopic cholecystectomy--a new technique.
Laparoscopic cholecystectomy is now the procedure of choice in all the gall bladder diseases and there is increase in the skills of surgeons with newer equipment. Normally the laparoscopic cholecystectomy is performed by using four ports or three ports. Two ports laparoscopic cholecystectomy is rarely performed as it demands greater expertise and skills. Also this technique is less expensive an...
متن کاملa New Resonant Converter Circuit for Reluctance
The purpose of this paper is to introduce a different type of converter circuit used to drive switched reluctance motors. It continues with detailed discussion on the resonant converter armed at minimizing or eliminating the transistors switching losses. Finally the drive has been tested on a disc-type reluctance motor for the perfomance and functionality.
متن کاملA new robust method for six-port reflectometer calibration
A new robust method for finding the parameters of Engen’s six-port-to-four-port reduction algorithm for sixport reflectometer calibration has been developed. Like other previously published methods, it uses a minimum of five loads with an unknown but constant absolute value of the reflection coefficient and unknown but well-distributed phases. However, the quality of the parameter estimates is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Advanced Computer Science and Applications
سال: 2019
ISSN: 2156-5570,2158-107X
DOI: 10.14569/ijacsa.2019.0100563