A Calorimetric Resistance Thermometer
نویسندگان
چکیده
منابع مشابه
Calorimetric readout of a superconducting proximity-effect thermometer
A proximity-effect thermometer measures the temperature dependent critical supercurrent in a long superconductor normal metal superconductor (SNS) Josephson junction. Typically, the transition from the superconducting to the normal state is detected by monitoring the appearance of a voltage across the junction. We describe a new approach to detect the transition based on the temperature increas...
متن کاملAn A - C Resistance Thermometer Bridge
r '-' A 400 Hz bridge des igned spec ifically fo r measurin g the res istances of platinum the rmometers is desc ribed. Wh en used in conjunction with a co nvent ional 25 ohm thermometer, the instrument ca n resolve a resistance change of 2 micro-ohm s or less, or about 20 microdegrees. It is believed to be in error by no more tha n 3 micro-ohms throughout the useful temperature ra nge of a con...
متن کاملResistance Thermometer Theory and Practice
1. BASIC THEORY The electrical conductivity of a metal depends on the movement of electrons through its crystal lattice. Due to thermal excitation, the electrical resistance of a conductor varies according to its temperature and this forms the basic principals of resistance thermometry. The effect is most commonly exhibited as an increase in resistance with increasing temperature, a positive te...
متن کاملA thermistor leaf thermometer.
An instrument is described which allows measurements of leaf temperature within about 0.3 C. It consists of a special thermistor probe, a small circuit box, and a standard ammeter. The circuit box can easily be fixed to the meter and contains a battery, which passes 0.3 milliampere through the thermistor, and also contains an integrated circuit amplifier, so that the meter reads 20 C full scale...
متن کاملA differential calorimetric approach
For the first time, calorimetric studies performed at very low temperature highlighted the preliminary and required conditions for further aggregation/coacervation of peptides from elastin in solution through the structural water reorganization around the peptides. For this purpose, we firstly characterized by turbidimetry and differential scanning calorimetry the synthetic S4 fragment peptide ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review
سال: 1917
ISSN: 0031-899X
DOI: 10.1103/physrev.9.205