A CFD-Based Parametric Thermal Performance Analysis of Supply Air Ventilated Windows

نویسندگان

چکیده

Ventilated windows have the potential to contribute both indoor air quality and energy efficiency in cold climates. A typical ventilated window functions as a solar collector under inward flow direction incident radiation. The is modification of multiple pane which drawn from outside heated through conduction, convection, radiation cavity. In this study, detailed parametric analysis was conducted investigate thermal performance their capacity preheat ventilation air. High-resolution 3D steady RANS computational fluid dynamic (CFD) simulations were performed for six geometries. Model results compared with measurements. following geometric characteristics evaluated detail: (i) height window, (ii) width cavity, (iii) location double-layered glazing, (iv) supply opening. suggested that taller cavities smaller cavity depth can provide higher incoming temperature. Windows inner glazing opening displayed better performance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Performance of a Double-pass Solar Air Heater

This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...

متن کامل

Thermal Performance of Traditional Windows Prepared for Historic Scotland Corrections and Clarifications Thermal Performance of Traditional Windows Improving the Thermal Performance of Traditional Windows Prepared for Historic Scotland by Summary of Report by the Thermal Performance of Traditional Windows

Corrections Page 17, Table 6: The in situ U-value from Lauriston Place for single glazing with secondary glazing has actually been 1.6 W/m 2 K instead of 2.3 W/m 2 K. Clarifications The U-values in this report are measured at the centre of the glass pane, and are not whole-window U-values; except for the U-value measured by the National Physical Laboratory, refer to Appendix 1, which is a whole...

متن کامل

a gender-based pragmatic analysis of the use of english compliment responses by iraqi efl students:a speech act perspective

تعارفات کنش های گفتاری هستند که افراد در زندگی روزمر? خود به منظور برقراری دوستی یا تداوم روابط مسالمت آمیز به کار می برند. ساز و کار تعارف مختص زبان انگلیسی یا هر زبان دیگری نیست و پدیده ای است جهانی و در همه زبانها حضور دارد. تفاوتی که از این نظر در زبانها و فرهنگ ها وجود دارد مربوط به پاسخ به این کنش گفتاری در گفتمان است. این مطالعه به بررسی تنوع پاسخ های انگلیسی و عربی به کنش گفتاری تعارف د...

Research on Effect of Ventilated Region to Grape Rain Shed Performance Based on CFD

Two different kinds of multi-span grape rain sheds are constructed and the wind field and rainfall field distribution are simulated based on CFD and computer simulation techniques. The airflow distribution, temperature variation, wind pressure distribution and rainfall vectors distribution are compared under two conditions with ventilated region and without ventilated area in multi-span grape r...

متن کامل

Analysis of Air Supply Type and Exhaust Location in Laboratory Animal Research Facilities Using CFD

The results from a computational fluid dynamics (CFD) study on the effect of air supply diffuser type and exhaust location in a typical animal research laboratory are presented. The results show that low-level exhausts produce higher temperatures in the room and cages, but the best in-cage ventilation (lowest CO 2 concentrations) compared with ceiling or high-level exhausts. Further, the study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14092420