A CHARGE-COUPLED DEVICE PHOTOMETRIC STUDY OF SOUTH HEMISPHERIC CONTACT BINARY AE PHOENICIS
نویسندگان
چکیده
منابع مشابه
Charge-coupled device area x-ray detectors
Charge-coupled device ~CCD! area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record the spatially resolved image. The various combinations of components that have been used to make CCD de...
متن کاملSurface imaging of late - type contact binaries II : H α 6563 Å emission in AE Phoenicis and YY Eridani
We present and discuss the Hα (λ = 6563Å) observations of the contact (W UMa type) binaries AE Phoenicis and YY Eridani, obtaineded in 1989, 1990 and 1995 with the CAT/CES telescope of the Southern European Observatory (ESO). In particular, we compare the intrinsic equivalent widths of both components with the NextGen theoretical models and the saturation limit. We find that the average Hα equi...
متن کاملA fast, direct x-ray detection charge-coupled device.
A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output po...
متن کاملa study of translation of english litrary terms into persian
چکیده هدف از پژوهش حاضر بررسی ترجمه ی واژه های تخصصی حوزه ی ادبیات به منظور کاوش در زمینه ی ترجمه پذیری آنها و نیز راهکار های به کار رفته توسط سه مترجم فارسی زبان :سیامک بابایی(1386)، سیما داد(1378)،و سعید سبزیان(1384) است. هدف دیگر این مطالعه تحقیق در مورد روش های واژه سازی به کار رفته در ارائه معادل های فارسی واژه های ادبی می باشد. در راستای این اهداف،چارچوب نظری این پژوهش راهکارهای ترجمه ار...
15 صفحه اولAn approximate two-dimensional transient analysis of charge transport in a buried-channel charge-coupled device
2014 A method for the approximate transient analysis of the BCCD is presented. The solution is obtained by considering only the nearly-linear Poisson/Laplace’s equation in a completelydepleted/charge-neutral region and subsequent estimate of carrier flow across the interface between the charged and neutral regions. Additional factors are introduced in the solution of the equations to ensure tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Astronomical Journal
سال: 2009
ISSN: 0004-6256,1538-3881
DOI: 10.1088/0004-6256/138/5/1465