A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
نویسندگان
چکیده
منابع مشابه
A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
BACKGROUND The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle ...
متن کاملEvaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
متن کاملVerification of Dose Calculation Accuracy of Rtp Systems by Monte Carlo Simulation
High dose rate brachytherapy has attained the good local control for cervix cancer because radioactive source can be put close to tumors, resulting in increasing the dose delivery per one fraction. However, quality assurance must be accompanied to reduce severe complication. We verified the dose distribution around the source by comparing measured dose with calculated dose by Radiation Therapy ...
متن کاملFast CPU-based Monte Carlo simulation for radiotherapy dose calculation.
Monte-Carlo (MC) simulations are considered to be the most accurate method for calculating dose distributions in radiotherapy. Its clinical application, however, still is limited by the long runtimes conventional implementations of MC algorithms require to deliver sufficiently accurate results on high resolution imaging data. In order to overcome this obstacle we developed the software-package ...
متن کاملGPU-based fast Monte Carlo simulation for radiotherapy dose calculation.
Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our recent progress toward the development of a graphics processing unit (GPU)-based MC dose calculation package, gDPM v2.0. It utilizes the parallel computation ab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiation Oncology
سال: 2014
ISSN: 1748-717X
DOI: 10.1186/s13014-014-0287-2