A colorimetric paper sensor for lactate assay using a cellulose-Binding recombinant enzyme
نویسندگان
چکیده
منابع مشابه
An automated colorimetric (tetrazolium salt) assay for serum lactate dehydrogenase.
The adaptation of a tetrazolium salt assay for serum lactate dehydrogenase to full automation is described. The tetrazolium salt, INT, (2-p-iodophenyl-3-p-nitrophenyl5-phenyl tetrazolium chloride) serves as the chromogenic indicator of the enzyme activity. Phenazine methosulfate serves as an intermediate electron carrier. Estimation requires only 5 mm. of incubation, and assays may be run at th...
متن کاملFabrication of a microfluidic paper-based analytical device by silanization of filter cellulose using a paper mask for glucose assay.
We developed a novel, low-cost and simple method for the fabrication of microfluidic paper-based analytical devices (μPADs) by silanization of filter cellulose using a paper mask having a specific pattern. The paper mask was penetrated with trimethoxyoctadecylsilane (TMOS) by immersing into TMOS-heptane solution. By heating the filter paper sandwiched between the paper mask and glass slides, TM...
متن کاملAn enzyme-coupled colorimetric assay for S-adenosylmethionine-dependent methyltransferases.
We report here an enzyme-coupled colorimetric assay for salicylic acid carboxyl methyltransferase (SAMT), which utilizes S-adenosyl-l-methionine (AdoMet or SAM) as the methyl donor. In this assay, S-adenosyl-l-homocysteine (AdoHcy or SAH), a common product of AdoMet-dependent transmethylation reactions, is first hydrolyzed by recombinant AdoHcy nucleosidase (EC 3.2.2.9) into adenine and S-ribos...
متن کاملA colorimetric assay for mucous glycoproteins using Alcian Blue [proceedings].
The present paper describes a simple, sensitive technique for measurement of respiratory mucous glycoproteins that involves their precipitation with the cationic dye Alcian Blue. The assay was adapted from that described by Whiteman (1973) for measurement of urinary glycosaminoglycans. This method is useful for measurement of mucins secreted in response to stimulating agents in isolated airway ...
متن کاملSensitive colorimetric assay for angiotensin converting enzyme in serum.
A sensitive colorimetric procedure has been developed for the assay of angiotensin converting enzyme (EC 3.4.15.1) in serum. Serum (10 microL) is incubated for 30 min with hippuryl-glycyl-glycine as described earlier (Clin Chem 28: 1352-1355, 1982). After a Folin-Wu deproteinization, the liberated glycyl-glycine is derivatized with a borate-buffered (pH 9.3) trinitrobenzenesulfonate solution (6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors and Actuators B: Chemical
سال: 2017
ISSN: 0925-4005
DOI: 10.1016/j.snb.2016.07.008