A commissioning procedure for breast intracavitary electronic brachytherapy systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A commissioning procedure for breast intracavitary electronic brachytherapy systems

In this work, we report a comprehensive quality assurance (QA) process for the commissioning of an Electronic Brachytherapy (EB) system at one of the first U.S. sites to apply the device clinically. Thus far, EB systems have been released only for intracavitary breast treatments. As such, EB as an Accelerated Partial Breast Irradiation (APBI) treatment modality is relatively unstudied and is un...

متن کامل

Interface dosimetry for electronic brachytherapy intracavitary breast balloon applicators

In this study, we evaluate the attenuation of the dose due to barium-impregnation in the region between the surface of an electronic brachytherapy (EBT) balloon applicator for accelerated partial breast irradiation (APBI) and the prescription point at 1 cm depth in tissue. To perform the study, depth dose curves were calculated using a general purpose multi-particle transport code (FLUKA) for a...

متن کامل

Commissioning and periodic tests of the Esteya® electronic brachytherapy system

A new electronic brachytherapy unit from Elekta, called Esteya(®), has recently been introduced to the market. As a part of the standards in radiation oncology, an acceptance testing and commissioning must be performed prior to treatment of the first patient. In addition, a quality assurance program should be implemented. A complete commissioning and periodic testing of the Esteya(®) device usi...

متن کامل

Brachytherapy dose‐volume histogram commissioning with multiple planning systems

The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA...

متن کامل

Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer

The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2008

ISSN: 1526-9914

DOI: 10.1120/jacmp.v9i3.2775