A Compact Microwave Microfluidic Sensor Using a Re-Entrant Cavity
نویسندگان
چکیده
منابع مشابه
A Compact Microwave Microfluidic Sensor Using a Re-Entrant Cavity
A miniaturized 2.4 GHz re-entrant cavity has been designed, manufactured and tested as a sensor for microfluidic compositional analysis. It has been fully evaluated experimentally with water and common solvents, namely methanol, ethanol, and chloroform, with excellent agreement with the expected behaviour predicted by the Debye model. The sensor's performance has also been assessed for analysis...
متن کاملHepa Filter Material Load Detection Using a Microwave Cavity Sensor
This paper presents a novel microwave cavity sensor application for the detection of HEPA filter particulate loading. The sensor resonates at 3.435GHz and 8.570GHz when empty, where the TM010 and TM020 modes dominate respectively. Experimental results show that the resonant frequency of the sensor shifts significantly when filters of different particulate loadings are presented to it. This is a...
متن کاملDevelopment of A Compact and Low Profile Cavity Backed Slot Antenna Using Microstrip Gap Waveguide Technology
Proof of concept of a cavity backed slot antenna based on inverted microstrip gap waveguide (IMGW) technology is presented. Since the antenna is operating based on the first resonating mode of the cavity, it is more compact compared to the ordinary cavity backed slot antennas in which the second cavity mode is used for radiation. Furthermore, the proposed antenna element introduces lower lo...
متن کاملMicrowave Chemical Sensor Using Substrate-Integrated-Waveguide Cavity
This research proposes a substrate-integrated waveguide (SIW) cavity sensor to detect several chemicals using the microwave frequency range. The frequency response of the presented SIW sensor is switched by filling a very small quantity of chemical inside of the fluidic channel, which also causes a difference in the effective permittivity. The fluidic channel on this structure is either empty o...
متن کاملA Re - entrant Cavity for Measurement of Complex Permeability in the Very - High - Frequency Region
Are-ent rant. cavity, cons~ructed for meas~ring . t h e initial complex permeability of magnetlC torolds III the very-~lgh-fre9uency region, IS described. Many of t he e lectrical and ,rnechamcal problems assOCIated wIth t he. development of an instrument of t his type are ?ons.ldered. The gen eral t~eory of pel:meablhty. measllremel? ts, using ~ re-~ntrant c!l:vity, IS discussed, and t he assO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2018
ISSN: 1424-8220
DOI: 10.3390/s18030910