A critical review of retrofitting methods for unreinforced masonry structures
نویسندگان
چکیده
منابع مشابه
Testing unreinforced masonry structures at reduced scale
When testing multi-story structures on a shaking table, most testing facilities require a reduced scale model. Producing scale test units at small scale is particularly challenging for unreinforced masonry structures. Previous work by other researchers showed that scaling of units and mortar joints is mandatory in order to obtain for the reduced scale masonry failure modes, which are similar to...
متن کاملTowards Displacement-Based Seismic Design of Modern Unreinforced Masonry Structures
Unreinforced masonry (URM) structures are known to be rather vulnerable to seismic loading. Modern URM buildings with reinforced concrete (RC) slabs might, however, have an acceptable seismic performance for regions of low to moderate seismicity. In particular in countries of moderate seismicity it is often difficult to demonstrate the seismic safety of modern URM buildings by means of force-ba...
متن کاملFlexural Tension in Unreinforced Masonry
Unreinforced masonry is that in which the tensile strength of the masonry is taken into consideration in design. Allowable out-of-plane tensile stress values are a function of the mortar type, such as Portland cement/lime mortar vs. masonry cement mortar or type M or S mortar vs. type N mortar. The allowable tensile stress is also a function of the masonry construction, such as tension parallel...
متن کاملInvestigating Efficiency of Shotcrete for Retrofitting Masonry Buildings
One of a feasible and efficient method to retrofit structures is spraying shotcrete which is widely applied around the world. Shotcrete is concrete with fine aggregates which are sprayed through a hose and by air pressure coat at high velocity onto a surface. In the current research, three masonry schools from different regions of Iran are selected. The retrofitted wall surfaces have been prepa...
متن کاملEffective stiffness of unreinforced brick masonry walls
Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Disaster Risk Reduction
سال: 2014
ISSN: 2212-4209
DOI: 10.1016/j.ijdrr.2013.12.004