A Design Method for Viscous Dampers Connecting Adjacent Structures
نویسندگان
چکیده
منابع مشابه
investigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Earthquake Response of Adjacent Structures with Viscoelastic and Friction Dampers
We study the seismic response of two adjacent structures connected with a dry friction damper. Each of them consists of a viscoelastic rod and a rigid block, which can slide without friction along the moving base. A simplified earthquake model is used for modeling the horizontal ground motion. Energy dissipation is taken by the presence of the friction damper, which is modeled by the set-valued...
متن کاملEquivalent Damping Ratios of Structures with Supplemental Viscous Dampers
The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...
متن کاملThe Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Built Environment
سال: 2020
ISSN: 2297-3362
DOI: 10.3389/fbuil.2020.00025