A direct procedure for the seismic design of frame structures with added viscous dampers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Application of a Direct Procedure for the Seismic Retrofit of a R/C School Building Equipped with Viscous Dampers

Several design methods aimed at sizing the viscous dampers to be inserted in building structures have been proposed in the last decades. Among others, the authors proposed a five-step procedure that guides the practical design from the choice of a target reduction in the seismic response of the structural system (with respect to the response of a structure without any additional damping devices...

متن کامل

Earthquake Analysis of Reinforce Concrete Framed Structures with Added Viscous Dampers

This paper describes the development of a numerical finite element algorithm used for the analysis of reinforced concrete structure equipped with shakes energy absorbing device subjected to earthquake excitation. For this purpose a finite element program code for analysis of reinforced concrete frame buildings is developed. The performance of developed program code is evaluated by analyzing of ...

متن کامل

Viscous microstructural dampers with aligned holes: design procedure including the edge correction.

The paper is a continuation of the works "Modelling of viscous damping of perforated planar micromechanical structures. Applications in acoustics" [Homentcovschi and Miles, J. Acoust. Soc. Am. 116, 2939-2947 (2004)] and "Viscous Damping of Perforated Planar Micromechanical Structures" [Homentcovschi and Miles, Sensors Actuators, A119, 544-552 (2005)] where design formulas for the case of an off...

متن کامل

The Effect of Viscous Dampers on Improvement of the Behavior of Tall Belt Truss Structures

Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Safety and Security Engineering

سال: 2017

ISSN: 2041-9031,2041-904X

DOI: 10.2495/safe-v7-n4-498-509