A dry-reagent strip for quantifying carbamazepine evaluated.
نویسندگان
چکیده
منابع مشابه
A dry-reagent strip for quantifying carbamazepine evaluated.
We examined a new colorimetric homogeneous immunoassay for carbamazepine based on the apoenzyme reactivation immunoassay system (ARIS) principle. The test, in dry-reagent strip format, is to be used with the Ames Seralyzer reflectance photometer. Within-run CVs (n = 20) were 3.0%, 2.7%, and 2.8% at 3.0, 6.1, and 12.1 mg/L; between-run CVs (n = 15, in 15 days) were 4.1%, 2.7%, and 1.9% at 6.0, 9...
متن کاملTwo dry-reagent systems evaluated for determinations of enzyme activities.
We evaluated the Kodak Ektachem DT60/DTSC and the Boehringer Mannheim Reflotron for measuring activity concentrations of six enzymes. The Ektachem CVs for low concentrations of aspartate aminotransferase and alanine aminotransferase were high. As compared with the Ektachem and a routine "wet-chemistry" system, values for aspartate aminotransferase and alanine aminotransferase were lower as meas...
متن کاملReagent - Strip Urinalysesfor Glucose
deficiency. It is not applicable to newborn or mass screening with use of ifiterpaper specimens, but is satisfactory for liquid urine screening. In one variant of sulfite oxidase deficiency, due to a defect of its molybdate cofactor metabolism, the concentration of uric acid in serum is decreased. Thus, an unexplained low serum uric acid, especially in a young patient with neurologic abnormalit...
متن کاملMolecular beacon-functionalized gold nanoparticles as probes in dry-reagent strip biosensor for DNA analysis.
The highly specific molecule recognition properties of molecular beacons (MB) are combined with the unique optical properties of gold nanoparticles (Au-NPs) for the development of a dry-reagent strip-type nucleic acid biosensor (DSNAB) that enables sensitive and low-cost detection of nucleic acid samples within 15 min.
متن کاملMoving Enzyme-Linked ImmunoSorbent Assay to the Point-of-Care Dry- Reagent Strip Biosensors
In this work, we described a point-of-care (POC) dry-reagent strip biosensor (DRSB) based on enzyme tracers and portable strip reader for simple, low-cost and sensitive assay of protein detection in minutes. Horseradish Peroxidase (HRP) and Rabbit IgG (R-IgG) were used as a model system for the demonstration of the proof-of-concept. The sandwich-type immunoreactions were performed on the DRSB a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1988
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/34.2.388