A dry-reagent strip for quantifying carbamazepine evaluated.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A dry-reagent strip for quantifying carbamazepine evaluated.

We examined a new colorimetric homogeneous immunoassay for carbamazepine based on the apoenzyme reactivation immunoassay system (ARIS) principle. The test, in dry-reagent strip format, is to be used with the Ames Seralyzer reflectance photometer. Within-run CVs (n = 20) were 3.0%, 2.7%, and 2.8% at 3.0, 6.1, and 12.1 mg/L; between-run CVs (n = 15, in 15 days) were 4.1%, 2.7%, and 1.9% at 6.0, 9...

متن کامل

Two dry-reagent systems evaluated for determinations of enzyme activities.

We evaluated the Kodak Ektachem DT60/DTSC and the Boehringer Mannheim Reflotron for measuring activity concentrations of six enzymes. The Ektachem CVs for low concentrations of aspartate aminotransferase and alanine aminotransferase were high. As compared with the Ektachem and a routine "wet-chemistry" system, values for aspartate aminotransferase and alanine aminotransferase were lower as meas...

متن کامل

Reagent - Strip Urinalysesfor Glucose

deficiency. It is not applicable to newborn or mass screening with use of ifiterpaper specimens, but is satisfactory for liquid urine screening. In one variant of sulfite oxidase deficiency, due to a defect of its molybdate cofactor metabolism, the concentration of uric acid in serum is decreased. Thus, an unexplained low serum uric acid, especially in a young patient with neurologic abnormalit...

متن کامل

Molecular beacon-functionalized gold nanoparticles as probes in dry-reagent strip biosensor for DNA analysis.

The highly specific molecule recognition properties of molecular beacons (MB) are combined with the unique optical properties of gold nanoparticles (Au-NPs) for the development of a dry-reagent strip-type nucleic acid biosensor (DSNAB) that enables sensitive and low-cost detection of nucleic acid samples within 15 min.

متن کامل

Moving Enzyme-Linked ImmunoSorbent Assay to the Point-of-Care Dry- Reagent Strip Biosensors

In this work, we described a point-of-care (POC) dry-reagent strip biosensor (DRSB) based on enzyme tracers and portable strip reader for simple, low-cost and sensitive assay of protein detection in minutes. Horseradish Peroxidase (HRP) and Rabbit IgG (R-IgG) were used as a model system for the demonstration of the proof-of-concept. The sandwich-type immunoreactions were performed on the DRSB a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 1988

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/34.2.388