A dual optic accommodating foldable intraocular lens

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SCIENTIFIC REPORT A dual optic accommodating foldable intraocular lens

Aim: To design an accommodating intraocular lens with extended accommodative range that can be adapted to current standard phacoemulsification and endocapsular implantation technique. Method: Ray tracing analysis and lens design; cadaver eye implantation. Results: Ray tracing analysis indicated that axial movement of an exaggerated converging anterior optic linked by spring loaded haptics to a ...

متن کامل

Clinical performance of a new aspheric dual-optic accommodating intraocular lens

PURPOSE To describe the clinical performance of a new dual-optic intraocular lens (IOL) with an enhanced optic profile designed to mimic natural accommodation. PATIENTS AND METHODS Prospective multicenter clinical study with the new dual-optic aspheric accommodating IOL (Synchrony Vu) in 74 patients (148 eyes) undergoing cataract surgery. Refractive target was emmetropia. Examinations at 1 mo...

متن کامل

Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens

Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommoda...

متن کامل

near visual performance results of the accommodating intraocular lens (tetraflex)® in comparison to monofocal foldable intraocular lens

purpose : to evaluate the near visual performance of an accommodative intraocular lens (iol) tetraflex, in comparison to a standard monofocal foldable iol in cataract surgery. setting: eye research center , farabi eye hospital , department of ophthalmology, tehran university of medical sciences, iran . methods : forty six eyes of 23 patients with cataract underwent phacoemulsification and accom...

متن کامل

Optical principles, biomechanics, and initial clinical performance of a dual-optic accommodating intraocular lens (an American Ophthalmological Society thesis).

PURPOSE To design and develop an accommodating intraocular lens (IOL) for endocapsular fixation with extended accommodative range that can be adapted to current standard extracapsular phacoemulsification technique. METHODS Ray tracing analysis and lens design; finite element modeling of biomechanical properties; cadaver eye implantation; initial clinical evaluation. RESULTS Ray tracing anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Ophthalmology

سال: 2003

ISSN: 0007-1161

DOI: 10.1136/bjo.87.9.1083