This paper introduces a fault-tolerant shunt active power filter (SAPF). The novility in of this work is that it poposes solutions to increase the reliability maintain its operation under single-phase open-circuit fault SAPF. will whole system. SAPF composed 4-leg 27-level inverter based on asymmetric cascaded H-bridge topology. If an introduced SAPF, special control technique be implemented and redundant leg activated. can do many tasks healthy operating conditions post open circuit depending state charge (SOC) batteries. It mitigate harmonics system, improve factor system by injecting reactive power, inject real proposed tested simulated MATLAB/Simulink results have shown significant improvement total distortion (THD) source current from 13.9% 3.9% normal condition 42% 8.4% fault.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three Level Inverter Based Shunt Active Power Filter Using Multi-Level Hysteresis Band Current Controller

In this paper, a three-level inverter based Shunt Active Power Filter (SAPF) using Multi-Level Hysteresis Current Controller (MLHCC) is presented for solution of power quality problems in distribution system. A simulation model of SAPF is prepared in Matlab/Simulink environment. MLHCC is used for control of SAPF currents. In simulation study, it is considered that SAPF executes two tasks coveri...

متن کامل

Minimally Switched Shunt active Power Filter Inverter for Harmonic Mitigation

Active filters provide significant harmonic and reactive power compensation and are thereby widely accepted as devices for power quality enhancement.. Many research works have been done to improve the dynamic performance of active filters. Current research work focuses on implementing a Minimally Switched Shunt Active Power filter for power quality enhancement. Minimally switched grid interacti...

متن کامل

Harmonic Mitigation Using Inverter Based Hybrid Shunt Active Power Filter

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

متن کامل

Power Quality Improvement of a grid interconnected photovoltaic system by using Shunt Active Power Filter

This paper proposes the improved methodology of power quality in grid interconnected photo voltaic system by using shunt active power filter . With development of new functionalities solar energy based Photovoltaic cells are upcoming energy source with higher efficiency. Solar energy being naturally available in abundance and nonpolluting is one of the most promising sources. Excessive use of p...

متن کامل

Power quality enhancement using cascaded multilevel inverter based shunt hybrid active power filter

This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Power Electronics and Drive Systems

سال: 2021

ISSN: ['2722-2578', '2722-256X']

DOI: https://doi.org/10.11591/ijece.v11i2.pp1166-1177