A Fidelity-Embedded Regularization Method for Robust Electrical Impedance Tomography
نویسندگان
چکیده
منابع مشابه
A Fidelity-embedded Regularization Method for Robust Electrical Impedance Tomography.
Electrical impedance tomography (EIT) provides functional images of an electrical conductivity distribution inside the human body. Since the 1980s, many potential clinical applications have arisen using inexpensive portable EIT devices. EIT acquires multiple trans-impedance measurements across the body from an array of surface electrodes around a chosen imaging slice. The conductivity image rec...
متن کاملTotal Variation Regularization in Electrical Impedance Tomography
This paper presents an evaluation of the use of Primal Dual Methods for efficiently regularizing the electric impedance tomography (EIT) problem with the Total Variation (TV) functional. The Total Variation functional is assuming an important role in the regularization of inverse problems thanks to its ability to preserve discontinuities in reconstructed profiles. This property is desirable in ...
متن کاملFour-Dimensional Regularization for Electrical Impedance Tomography Imaging
This paper proposes 4-D EIT image reconstruction for functional EIT measurements. The approach directly accounts for 3-D interslice spatial correlations and temporal correlations between images in successive data frames. Image reconstruction is posed in terms of an augmented image x̃ and measurement vector ỹ, which concatenate the values from the d previous and future frames. Image reconstructio...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملMagnetic detection electrical impedance tomography with total variation regularization.
Magnetic detection electrical impedance tomography (MDEIT) is an imaging modality that aims to reconstruct the cross-sectional conductivity distribution of a volume from the magnetic flux density surrounding an object. The MDEIT inverse problem is inherently ill-posed, necessitating the use of regularization. The most commonly used L(2) norm regularizations generate the minimum energy solution,...