A flexible calibration method for laser displacement sensors based on a stereo-target
نویسندگان
چکیده
منابع مشابه
Modification of Displacement Coefficient Method in Estimation of Target Displacement for Regular Concrete Bridges Based on ASCE 41-06 Standard
Displacement Coefficient Method (DCM) stipulated in the ASCE 41-06 standard is becoming the preferred method for seismic rehabilitation of buildings in many high-seismic-hazard countries. Applications of the method for non-building constructions such as bridges are beyond the scope of this standard. Thus its application to this kind of structure should be approached with care. Target displaceme...
متن کاملStructural Parameters Calibration for Binocular Stereo Vision Sensors Using a Double-Sphere Target
Structural parameter calibration for the binocular stereo vision sensor (BSVS) is an important guarantee for high-precision measurements. We propose a method to calibrate the structural parameters of BSVS based on a double-sphere target. The target, consisting of two identical spheres with a known fixed distance, is freely placed in different positions and orientations. Any three non-collinear ...
متن کاملA self-calibration method for a multi stereo-rig system based on robust 3D motion estimation
This paper discusses self-calibration method for a multi stereo-rig passive face recognition system with overlapping views of individual cameras. Two cameras fixed inside a rig can be easily calibrated in a factory environment so each rig will be considered individually calibrated. It is incredibly important to estimate relative positions and orientations of the stereo rigs with respect to each...
متن کاملA reagentless signal-on architecture for electronic, aptamer-based sensors via target-induced strand displacement.
Thrombin binding stabilizes the alternative G-quadruplex conformation of the aptamer, liberating the methylene blue (MB)-tagged oligonucleotide to produce a flexible, single-stranded DNA element. This allows the MB tag to collide with the gold electrode surface, producing a readily detectable Faradaic current at thrombin concentrations as low as approximately 3 nM.
متن کاملVision Sensor Calibration Method based on Flexible 3d Target and Invariance of Cross Ratio
A vision sensor calibration method based on flexible three-dimensional (3d) target and invariance of cross ratio is proposed. Flexible 3d target is obtained by moving planar target to different positions. According to the relative position relationship of planar targets in the different positions, unify target points to the base coordinate frame of the flexible 3d target. Using the invariance o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement Science and Technology
سال: 2014
ISSN: 0957-0233,1361-6501
DOI: 10.1088/0957-0233/25/10/105103