A flow controlled expiratory valve

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow resistance of expiratory positive-pressure valve systems.

The flow-resistive characteristics of a variety of commercially available expiratory positive-pressure valve systems used to provide continuous positive airway pressure (CPAP) and positive end-expiratory pressure were evaluated. One flow-resistor and seven threshold-resistor expiratory pressure valve systems were set at 5, 10, 15, 20, and 25 cm H2O of expiratory pressure, and sinusoidal exhaled...

متن کامل

Investigation of the Flow and Cavitation in a Butterfly Valve

Since knowledge on hydrodynamic torque of a butterfly valve is very important for butterfly valve design, its hydrodynamic torque is investigated in this paper. In reality, the investigation of the loss coefficient and torque from some experiments will take a long time and a lot of money. This paper presents a statistical study of the flow past the butterfly valve in a static analysis using com...

متن کامل

Expiratory flow limitation.

The first major advance in understanding expiratory flow limitation of the lungs came with the description of isovolume pressure-flow curves. These curves documented the existence of a volume-dependent limit to maximal expiratory flow and led directly to the description of the maximal expiratory flow-volume (MEFV) curve. Definitive modeling of flow limitation awaited the description of a locali...

متن کامل

Differentiating inspiratory and expiratory valve malfunctions.

hyperemia directly after release of the blood pressure cuff. As stated in our article, we did not measure reactive hyperemia but performed our measurements in all groups after 20 min of reperfusion. It is, therefore, unlikely that reactive hyperemia caused the observed differences between groups. We agree that further studies are needed to clarify more the mechanisms of helium preconditioning i...

متن کامل

Peak expiratory flow at altitude.

The mini Wright peak flow meter is a useful, portable instrument for field studies but being sensitive to air density will under-read at altitude. True peak expiratory flow will increase at altitude, however, because of the decreased air density, given that dynamic resistance is unchanged. The effect of simulated altitude on peak expiratory flow (PEF) was determined in six subjects with both th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 1979

ISSN: 0003-2409,1365-2044

DOI: 10.1111/j.1365-2044.1979.tb06391.x