A Four-Probe Method Using Different Probe Spacings for Measurement and Exact Reconstruction of Parallel Profiles
نویسندگان
چکیده
منابع مشابه
Design and Simulation of piezorestive pressure sensor for AFM Probe the displacement measurement
investigating pressure applied in surface vertically that is done by use of mechanical procedures isn’t efficient to measure pressure applied in inner surface of reservoir or pipes having gas due to entering pressure into whole walls and different surfaces. So, in order to measure this kind of pressure, several studies were conducted in past decades and also various procedures were proposed tha...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
طراحی و ساخت دستگاه four-point probe station
یکی از ویژگی های اساسی مواد هادی مقاومت الکتریکی آن هاست که با داشتن تعداد الکترونهای آزاد لایه ظرفیت می توان مقاومت الکتریکی آن ماده را پیدا نمود. با اندازه گیری مقاومت الکتریکی مواد می توان ویژگیها و مشخصات ماده را تعیین نمود. در این پایان نامه بنا داریم به اندازه گیری مقاومت الکتریکی با استفاده چهار پراب همراستا با فاصله ثابت از هم که در تماس با سطح یک ویفر سیلیکونی هستند اقدام کنیم. در عم...
SWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Sciences
سال: 2019
ISSN: 2076-3417
DOI: 10.3390/app9235216