A Hybrid Modular Interline Current Flow Controller for Meshed HVDC Grids
نویسندگان
چکیده
In meshed high-voltage direct current (HVdc) grid, the flows through lines cannot be controlled with sufficient freedom without additional power electronics-based devices, namely flow controller (CFC). this article, a novel hybrid modular interline CFC is proposed based on H-bridge submodules and thyristor valves. Due to its modularity, particularly suitable for applications requiring high voltage large capacity. The circuit structure, operation principle, parameter design are presented. addition, control strategy developed CFC. Simulations carried out using four-terminal HVdc grid verify effectiveness of topology strategy. A downscaled prototype built, which further validates
منابع مشابه
A Hybrid Reliability Evaluation Method for Meshed VSC-HVDC Grids
Haipeng Xie 1, Zhaohong Bie 1,*, Yanling Lin 1 and Chao Zheng 2 1 The State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China; [email protected] (H.X.); [email protected] (Y.L.) 2 The Department of Research and Application of New Technology, China Electric Power Research Institution, Beijing 100192, China; zhengch@epri....
متن کاملPower System Stability Enhancement using Interline Power Flow Controller
FACTS technology improves the power system stability by providing the necessary compensation to transmission lines. Interline Power Flow Controller (IPFC) is one such unique concept for exchange of power flow in case of interconnected systems. In this paper, an IPFC is proposed to improve the voltage stability of a given power system network consisting of three transmission lines. The gate trig...
متن کاملThe Hybrid HVDC Breaker An innovation breakthrough enabling reliable HVDC grids
Existing mechanical HVDC breakers are capable of interrupting HVDC currents within several tens of milliseconds, but this is too slow to fulfill the requirements of a reliable HVDC grid. HVDC breakers based on semiconductors can easily overcome the limitations of operating speed, but generate large transfer losses, typically in the range of 30 percent of the losses of a voltage source converter...
متن کاملRequirements for Fault Protection in HVDC Grids
Conventional Voltage Source Converters (VSC) cannot interrupt DC fault currents and DC circuit breakers are not yet commercially available for HVDC power ratings. Thus, the protection of VSC-HVDC systems is still an obstacle for the development of this technology. The features of VSC-HVDC systems make them suitable for implementing HVDC grids. Nevertheless, HVDC grids are more complex than poin...
متن کاملA Generalized Modular Multilevel Current Source Inverter
This paper proposes a novel topology of multilevel current source inverter which is suitable to apply in low/medium voltage. The proposed topology is capable of producing desirable bidirectional output current levels. Furthermore, it can employ symmetrical DC current sources as well as asymmetrical ones which is a significant advantage. Asymmetrical mode makes it possible to generate a great nu...