A 3D Forward and Back-Projection Method for X-Ray CT Using Separable Footprint
The computation burden of cone-beam forward and back-projectors is one of the greatest challenges facing iterative methods for 3D image reconstruction in CT. This paper describes a new separable footprint (SF) projector. It takes advantage of small polar angles of X-rays in cone-beam geometry to approximate the voxel footprint functions as 2D separable functions with simple rectangular function...
متن کامل3D Forward and Back-Projection for X-Ray CT Using Separable Footprints with Trapezoid Functions
The greatest impediment to practical adoption of iterative methods for X-ray CT is the computation burden of cone-beam forward and back-projectors. Moreover, forward and back-projector accuracy is also crucial to iterative reconstruction methods. We previously described a computationally efficient projector that approximates the voxel footprint functions by the 2D separable products of trapezoi...
متن کاملA look-up table based approach to characterize crystal twinning for synchrotron X-ray Laue microdiffraction scans
An automated method has been developed to characterize the type and spatial distribution of twinning in crystal orientation maps from synchrotron X-ray Laue microdiffraction results. The method relies on a look-up table approach. Taking into account the twin axis and twin plane for plausible rotation and reflection twins, respectively, and the point group symmetry operations for a specific crys...
متن کاملreproducible x-ray projection geometry in endodontic practice
introduction: clinical application of radiography in endodontic practice is affected by reproducibility in the orientation of the x-ray source, image receptor and object. the inability of dentists to locate intra oral films or sensors in appropriate positions in different cases can cause complications in the performance of endodontic therapy. commercially available film holder (endoray) and con...
متن کاملLook up Table Based Low Power Analog Circuit Testing
In this paper, a method of low power analog testing is proposed. In spite of having Oscillation Based Built in Self-Test methodology (OBIST), a look up table based (LUT) low power testing approach has been proposed to find out the faulty circuit and also to sort out the particular fault location in the circuit. In this paper an operational amplifier, which is the basic building block in the ana...