A magnetic blood oxygenator

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A mechanical heart and turbulence oxygenator.

AGREAT variety of perfusion piunps and blood oxygenators have been described during the past 80 years. A review of the necessary qualifications for such devices is given in part by Bjork and by Dubbleman. During the past six years the author has designed, constructed and tested several heartlung machines. This report describes and discusses the one which as of 1952 showed the greatest possibili...

متن کامل

Membrane Oxygenator with a Built-In Hemoconcentrator

In order to facilitate the handling of cardiopulmonary bypass (CPB) and simplify the circuit, we have developed a new membrane oxyganator with a hemofiltration function. The hollow fiber units for gas exchange and hemofiltration were combined in concentric circles in a cylindrical housing. The total priming volume was 190 ml. Because we used a silicon-coated hollow fiber membrane for gas exchan...

متن کامل

Heart pump and oxygenator.

1124 T ms PAPER is a general review of the development of the artificial heart-lung to facilitate open-heart surgery. At the close of World War II many centers began investigating the possibility of total cardiac bypass. Oven the past decade, pump oxygenerators of various types have become popular and recent clinical successes throughout the world have given further impetus to the study of prob...

متن کامل

Extraction of Nitroglycerin by a Membrane Oxygenator

This study examined the extraction efficiency of a membrane oxygenator for nitroglycerin (NTG). An In-Vitro cardiopulmonary bypass circuit was constructed to mimic clinical conditions. A NTG solution (150 ng/ml) was placed into the circuit via a glass cardiotomy reservoir and circulated at 5 Ll min for 60 min. Analysis of NTG samples obtained during the study showed that the oxygenator initiall...

متن کامل

Numerical analysis of the effects of a high gradient magnetic field on flowing erythrocytes in a membrane oxygenator

This study was carried out to clarify the effect of a high gradient magnetic field on pressure characteristics of blood in a hollow fiber membrane oxygenator in a solenoid coil by means of numerical analysis. Deoxygenated erythrocytes are paramagnetic, and oxygenated erythrocytes are diamagnetic. Blood changes its magnetic susceptibility depending on whether it is carrying oxygen or not. Motion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Physiology

سال: 1934

ISSN: 0022-3751

DOI: 10.1113/jphysiol.1934.sp003155