A method for rapid computation of maximum intensity projection images
نویسندگان
چکیده
منابع مشابه
An effective preprocessing method for fast hierarchical maximum intensity projection
Real-time processing and visualization of 3D image data are the most important requirements for medical imaging. Among various 3D visualization methods, maximum intensity projection (MIP) is a useful tool to visualize 3D medical images. The processing time of the MIP depends on the number of voxels of the 3D data. Therefore, it is very difficult to realize the MIP of the 3D medical images in re...
متن کاملMaximum Intensity Projection at
Maximum Intensity Projection (MIP) is a volume rendering technique which is used to extract high-intensity structures from volumetric scalar data. At each pixel the highest data value encountered along the corresponding viewing ray is determined. MIP is commonly used to extract vascular structures from medical MRI data sets, i.e., angiography. The usual way to compensate for the loss of spatial...
متن کاملDepth-Enhanced Maximum Intensity Projection
The two most common methods for the visualization of volumetric data are Direct Volume Rendering (DVR) and Maximum Intensity Projection (MIP). Direct Volume Rendering is superior to MIP in providing a larger amount of properly shaded details, because it employs a more complex shading model together with the use of user-defined transfer functions. However, the generation of adequate transfer fun...
متن کاملReal-Time Maximum Intensity Projection
Maximum Intensity Projection (MIP) is a volume rendering technique which is used to extract high-intensity structures from volumetric data. At each pixel the highest data value encountered along the corresponding viewing ray is determined. MIP is commonly used to extract vascular structures from medical MRI data sets (angiography). The usual way to compensate for the loss of spatial and occlusi...
متن کاملLmip: Local Maximum Intensity Projection | a New Rendering Method for Vascular Visualization |
In order to clearly depict densitometric as well as geometric information in vascular visualization from 3D data such as MR and CT angiographies, a new visualization method called local maximum intensity projection (LMIP) is proposed. LMIP is an extended version of MIP (maximum intensity projection). LMIP di ers from MIP in that the latter method selects the maximum value along an optical ray, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Digital Imaging
سال: 1997
ISSN: 0897-1889,1618-727X
DOI: 10.1007/bf03168702