A Monte Carlo Simulation of Neutron Instrument Resolution Functions

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

A New Approach for Monte Carlo Simulation of RAFT Polymerization

In this work, based on experimental observations and exact theoretical predictions, the kinetic scheme of RAFT polymerization is extended to a wider range of reactions such as irreversible intermediate radical terminations and reversible transfer reactions. The reactions which have been labeled as kinetic scheme are the more probable existing reactions as the theoretical point of view. The ...

متن کامل

Monte Carlo tool for neutron optics and neutron scattering instrument design

Unlike x-ray generators, neutron sources have inherently low bri ghtness, and care must be exerted in the design of neutron scattering instruments and their coupling to the source to ensure optimal use of the beam. We present a general, versatile Monte Carlo tool for the computer simulation of neutron optics and neutro n scattering instruments that allows a user to produce computer models of an...

متن کامل

A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom

Background: Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical targeting with neutron irradiation. However, monitoring the boron distribution is a fundamental problem in BNCT. Prompt gamma rays emitted by boron capture reaction can be used to address the issue. Materials and Methods: The general-purpose Monte Carlo toolkits Geant4 and MCNP were used for the simu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Physical Society of Japan

سال: 2013

ISSN: 0031-9015,1347-4073

DOI: 10.7566/jpsjs.82sa.sa037