A New Control Method of Single-Phase Shunt Active Filters Using the Correlation and Cross-Correlation Coefficients
نویسندگان
چکیده
منابع مشابه
Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays
The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...
متن کاملSingle-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملApplicability improvement and hysteresis current control method simplification in shunt active filters
Hysteresis current control method is vastly used in PWM inverters because of simplicity in performance, fast control response and good ability in limiting peak current. However, switching frequency in hysteresis current control method with fixed bandwidth has large variation during a cycle and therefore causes non-optimal current ripple generation in output current. One of basic problems in imp...
متن کاملPredicting the coefficients of the Daubert and Danner correlation using a neural network model
In the present research, three different architectures were investigated to predict the coefficients of the Daubert and Danner equation for calculation of saturated liquid density. The first architecture with 4 network input parameters including critical temperature, critical pressure, critical volume and molecular weight, the second architecture with 6 network input parameters including the on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 2005
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.125.1008